4
Mounting and installation
32
Festo – GDCP-CMCA-INST-EN – 1211a – English
4.2.10
Connect kinematic drives
Note
In the control cabinet design, the motor and encoder cables are guided through the
right one of the two cut-outs on the bottom of the control cabinet.
•
Connect the axis drives to the motor controller corresponding to the accompanying
motor controller description.
4.2.11
Connect limit switches
Terminal strip
Terminal
Description
Limit switch
Axis
X4
411
+24 V DC
1
1
441
0 V DC
416
Signal output
412
+24 V DC
2
442
0 V DC
417
Signal output
413
+24 V DC
1
2
443
0 V DC
418
Signal output
414
+24 V DC
2
444
0 V DC
419
Signal output
411
+24 V DC
1
3
Only with
characteristic
A2, A3, A4,
A5, A7, A8
441
0 V DC
446
Signal output
412
+24 V DC
2
442
0 V DC
447
Signal output
413
+24 V DC
1
4
Only with
characteristic
A3, A5, A8
443
0 V DC
448
Signal output
414
+24 V DC
2
444
0 V DC
449
Signal output
Tab. 4.19