3
Overview
Festo – GDCP-CMCA-INST-EN – 1211a – English
17
3.3.2
Control and signal elements on the control cabinet CMCA-…-CC-…/CMCA-…-CS-…
5
6
2
3
4
1
1
Illuminated push-button (S20/P20) “quit emergency stop”: Confirms unlocking of the emergency
stop circuit
2
Indicator light (P21) “external emergency stop”: External emergency stop circuit triggered
3
Indicator light (P4) “automatic control”: automatic operation active
4
Key switch (S2) “automatic/manual”: Switch between automatic and manual override
The switch is only active when the “local” operating mode has been selected by means of link
plug operating mode selection (
Tab. 4.17). In case of “external” operating mode, the switch is
without effect.
5
Indicator light (P5) “manual control”: manual operation active
6
Key switch (S3) “brake release”: releases the motor brakes (only possible in manual override and
in combination with the enabling button on the handheld terminal)
Fig. 3.2
Note
The labels for marking the control elements in German are also included in the control
cabinet.