CLR−...
Festo CLR−... 0912d English
32
3. Turn the clamping finger with a spanner
wrench. The clamping finger will then be
released from the piston rod.
For counter holding, the maximum per
mitted torque on the guide sleeve must
not
be exceeded (see chapter Mechanical
installation").
A suitable pull−off device must be used if
the clamping finger sticks.
S
Order the wearing parts as specified.
S
Always send the defective product to Festo.
S
Make sure that the CLR−... is overhauled only by our repair service.
The repair process calls for delicate setting work.
Please describe the fault and the operating conditions in your correspondence.
11
Accessories
Designation
Type
Foot mounting
HNA−...
Flange mounting
FNC−...
Start−up valve
HEL−.../HEM−...
One−way flow control valve
GRLA−...
Non−return valve
HGL−...
Compressed air reservoir
VZS−...
Proximity switch
SME−8−.../SMT−8−...
Clamping finger
CLR−...FS
Fig.23
Fig.22
Summary of Contents for CLR-12
Page 99: ...CLR Festo CLR 0912d 99...