Distributing Pro Station
© Festo Didactic
8117962
59
12
Commissioning
12.1
General information on the use of MPS Stations
MPS stations are generally shipped:
•
Fully assembled
•
Individually adjusted and ready for use
•
Pre-commissioned
•
Tested.
When stations are combined, the mechanical setup as well as sensor positions and
settings may have to be changed.
Commissioning is normally limited to visual inspection in order to ensure correct tubing connections, wiring
and operating voltage supply.
All components, tubing connections and cabling are clearly identified, so that all of the connections can be
readily restored as required.
12.2
Technical equipment of the workstation
You will require the following in order to commission the MPS station with the sample programs:
•
The assembled and adjusted MPS station
•
A control console
•
A PLC board with 16 digital inputs and outputs
•
One power pack 24 V DC, 4 A, ≤ 100 W output power, SELV/PELV lim
ited power source (LPS)
•
Compressed air supply: 600 kPa (6 bar)
•
A PC with installed PLC programming software
•
4 I/O cables (SysLink)