Distributing Pro Station
© Festo Didactic
8117962
53
Digital 3
Function
SysLink
Color
Designation
I0
13
Grey-pink
Gate valve magazine 3 retracted
I1
14
Red-blue
Gate valve magazine 3 advanced
I2
15
White-green
Magazine 3 empty
I3
16
Brown-green
Activate magazine 3
I4
17
White-yellow
I5
18
brown-yellow
I6
19
White-gray
I7
20
Grey-brown
Q0
1
White
Advance gate valve magazine 3
Q1
2
Brown
Indicator light magazine 3 activated
Q2
3
Green
Q3
4
Yellow
Q4
5
Grey
Q5
6
Pink
Q6
7
Blue
Q7
8
Red
24 V A
9+10
black
24 V power supply for outputs
24 V B
21+22
White-pink
24 V power supply for inputs
GND A
11
brown-pink
0 V power supply for outputs
GND A
12
purple
0 V power supply for outputs
GND B
23+24
White-blue
0 V power supply for inputs
Cable jumpers are connected from emergency stop to bit 1.5 on all PLC EduTrainer
Universal Preferred Versions MPS.