3. Mechanical installation
12
Festo GDCP-CDSA-SY-EN 1001a
3.
Mechanical installation
3.1
PlugIn housing CAMI-C
The PlugIn housing CAMI-C serves for integrating the teach pendant to the machine/
system and for connecting to the multi-axis controller CMXR-C1. It is fitted into the wall of
the control cabinet and has the following connections:
1
Cable screw connector for connecting
cable NESC with cables for voltage
supply, permission button,
EMERGENCY STOP and Ethernet.
2
Ethernet connection
1
Fig. 3.1: PlugIn housing CAMI-C
Please note
The PlugIn housing and the teach pendant comply with protection
class III as per EN 1131-2 and EN 50178. The following must be
noted in this regard:
All voltages saved in the PlugIn housing or in the teach pendant
must be low safety voltages and therefore isolated from the low
voltage network with a safety transformer or similar.
2