DNCI−...
Festo DNCI−... 0610a English
26
Fitting electric components
S
Avoid external influences by magnetic or
ferritic parts in the vicinity of the measur
ing head (approx. 100 mm).
This will guarantee that the sensor func
tions faultlessly.
S
Insert the screw with cutting thread sup
plied into the hole for the earth connec
tion
9
.
This will ensure the electrical contact in
spite of the anodizing layer.
S
Connect the earth cable with low impedance (short cable with large cross−
sectional area) to the earth potential.
If the DNCI−... is used with electronic control:
S
Connect the measuring system to the connecting cable as described in the
manuals for type SPC... .
If the DNCI−... is used as a measuring cylinder:
S
Connect the measuring system as follows:
Pin
Cable colour
Designation
Pin assignment (view of plug)
1
black
+Ub
3
2
brown
0 V
2
3
4
3
red
Signal sine +
2
4
4
orange
Signal sine −
8
5
5
green
Signal cosine −
8
5
6
yellow
Signal cosine +
1
6
7
Screening/shield
Screening/earth
1
6
7
8
n.c.
7
Fig.14
Fig.13