background image

2009/06 – Subject to change

29

Internet: www.festo.com/catalogue/...

Valve terminals type 32 MPA

Key features – Pneumatic components

Blanking plate

Plate without valve function for

reserving valve positions on a valve

terminal.

Valves and blanking plates are

attached to the manifold block using

two screws.

Valve function

Code

Circuit symbol

Size

Description

y

1

2

p

L

For valve terminal only:

Blanking plate for vacant valve position

Compressed air supply and venting

Pneumatic interface

The valve terminal MPA can be sup-

The main supply to the valve terminal

These vents are located on the

p

plied with air at one or more points.

This ensures that the valve terminal

will always have a sufficient supply of

air and that this air will be vented,

even with large-scale expansions.

pp y

is located on the pneumatic interface,

which links the electrical and the

pneumatic parts. Additional provision

is made for a number of supply plates.

Venting is either via integrated flat

plate silencers or common lines for

pneumatic interface as well as on the

supply plates.

In the case of ducted exhaust, at least

one additional supply plate is re-

quired that then contains the exhaust

port for the pilot air supply (port

Supply plate

plate silencers or common lines for

ducted exhaust.

port for the pilot air supply (port

82/84).

ducted exhaust.

82/84).

Pilot air supply

The port for the main pneumatic

supply is located on the pneumatic

interface.

The ports differ for the following types

of pilot air supply:

Internal

External

Internal pilot air supply

Internal pilot air supply can be

selected if the required working

pressure is between 3 and 8 bar.

The pilot air supply is then branched

from the compressed air supply 1 in

the pneumatic interface using an

internal connection. Port 12/14 is

sealed with a blanking plug.

External pilot air supply

If the supply pressure is less than

3 bar or greater than 8 bar, you must

operate your MPA valve terminal with

external pilot air supply.

In this case the pilot air is addition-

ally supplied via port 12/14 on the

pneumatic interface.

-H-

Note

If a gradual pressure build-up in the

system using a soft-start valve is

chosen, an external pilot air supply

should be connected so that the

control pressure applied during

switch-on is already very high.

Summary of Contents for 32 MPA

Page 1: ...Valve terminals type 32 MPA...

Page 2: ...a later date Further manifold blocks can be assembled using just three screws and sturdy separating seals on metal separator plates Integration of innovative function modules possible Manual regulator...

Page 3: ...2 way valve normally open external compressed air supply Manual pressure regulators Proportional pressure regulators Pressure sensor All valves have the same compact dimensions with an overall length...

Page 4: ...ording to your order specifications and are individually tested This reduces the assembly and installation time to a minimum The valve terminal type 32 is ordered using the order code Ordering system...

Page 5: ...correct polarity The valve terminal with AS interface is available in the following versions With two to eight modular valve positions max 8 solenoid coils This corresponds to 2 to 8 MPA1 or 2 to 8 MP...

Page 6: ...id coils Versions Profibus DP ProfiNet Interbus DeviceNet connection CANopen CC Link Ethernet IP Front End Controller Remote Front End Controller Remote I O Modbus TCP Profinet IO EtherCAT CPX termina...

Page 7: ...ed by loosening these screws This ensures that the valve terminal can be rapidly and reliably extended Modular electrical peripherals The manner in which the valves are actuated differs according to w...

Page 8: ...signation Brief description Page Internet 1 Solenoid valve MPA1 69 2 Manual override Non detenting turning with detent per solenoid coil 3 Cover cap for manual override Conversion from detenting non d...

Page 9: ...in order to control the force of the triggered actuator 4 3 2 1 7 6 5 Designation Brief description Page Internet 1 Solenoid valve MPA2 69 2 Manual override Non detenting turning with detent per sole...

Page 10: ...plug AS interface The manifold blocks are either prepared for 2 or 4 single solenoid valves 2 or 4 double solenoid valves depending on the size Double solenoid valve positions can be equipped with an...

Page 11: ...ant position size 1 74 5 Mounting Optional for valve terminal mounting on supply plate 71 6 Flat plate silencer 7 Exhaust plate For ducted exhaust air 74 8 Regulator plate Size 2 70 9 Solenoid valve S...

Page 12: ...fieldbus The manifold blocks are either prepared for 2 or 4 single solenoid valves 2 or 4 double solenoid valves depending on the size Double solenoid valve positions can be equipped with any valve o...

Page 13: ...7 Flat plate silencer 8 Exhaust plate For ducted exhaust air 74 9 Mounting Optional for valve terminal mounting on the manifold block of the proportional pressure regulator 71 aJ Electrical module For...

Page 14: ...n plug connection is designed as a removable 25 pin Sub D connection to IP65 The cable can be selected when ordering 2 5 m 5 m 10 m Each can be used for max 8 or 24 valves 1 2 3 4 5 6 7 Designation Br...

Page 15: ...code 32P for the pneumatic components 52E for the electrical components MPA valve terminals with AS interface connection can be expanded by up to 8 solenoid coils 4 2 3 1 5 Designation Brief descript...

Page 16: ...the pneumatic components 56E for the electrical components MPA valve terminals with CPI connection can be expanded by up to 32 solenoid coils 3 1 2 4 Designation Brief description Page Internet 1 Fla...

Page 17: ...lenoid coils per manifold block can actuate 64 solenoid coils Each valve position can be equipped with any valve or a blanking plate The rules for CPX apply to the equipment that can be used in combin...

Page 18: ...sing two screws which means that they can be easily replaced The mechanical sturdiness of the manifold block guarantees excellent long term sealing Blanking plates can be replaced by valves at a later...

Page 19: ...n Reversible Suitable for vacuum E 5 3 way valve Mid position exhausted1 Mechanical spring return Reversible Suitable for vacuum X 1x 3 2 way valve single solenoid Normally closed External compressed...

Page 20: ...eumatic spring return Operating pressure 3 bar Vacuum at port 3 5 only 1 If neither solenoid coil is energised the valve moves to its mid position by means of spring force If both coils are energised...

Page 21: ...ents 2 1 3 1 VMPA2 valve 2 Pressure regulator plate 3 Manifold block Vertical stacking Pressure regulator plate An adjustable pressure regulator can be installed between the manifold block and the val...

Page 22: ...the pressure from the valve terminal is always present An equal working pressure is required at working ports 2 and 4 A lower working pressure e g 3 bar than the operating pressure present at the valv...

Page 23: ...eam of the valve in duct 3 the unregulated pressure from duct 1 is in duct 5 The regulated air is then supplied to duct 2 The valve is thus operated in reversible mode During venting the exhaust flow...

Page 24: ...ck via the intermediate plate to duct 5 Application examples When instead of the operating pressure of the valve terminal a different pressure is required in duct 4 When fast exhaust venting is requir...

Page 25: ...r plate for port 2 B regulator PC VMPA2 B8 R2C2 C 10 Regulates the operating pressure in duct 2 downstream of the directional control valve PH VMPA2 B8 R2C2 C 06 Pressure regulator plate for port 4 A...

Page 26: ...ut pressure until it reaches the setpoint value The proportional pressure regulator has an additional supply connection to achieve the constant pressure supply required for high control quality The pr...

Page 27: ...ent This process runs continuously so changes in the reference variable are always detected However a system deviation will also appear if the refer ence variable is constant but the con trolled varia...

Page 28: ...o the maximum output pressure full scale Response sensitivity Repetition accuracy reproducibility 3 61 bar 3 60 bar The response sensitivity of the device determines how sensitively one can change i e...

Page 29: ...n the supply plates In the case of ducted exhaust at least one additional supply plate is re quired that then contains the exhaust port for the pilot air supply port Supply plate plate silencers or co...

Page 30: ...10 bar suitable for vacuum V Internal pilot air supply ducted exhaust air Pilot air supply is branched internally from port 1 in the pneumatic interface Exhaust port 3 5 connection to pneumatic inter...

Page 31: ...ports Compressed air supply 1 Venting of the pilot air supply 82 84 and pressure compensation Exhaust air 3 5 Depending on your order the exhaust ducts are either ducted or vented via the flat plate s...

Page 32: ...ical circuits are permissible to the right of the electrical supply plate H Note Max 24 of 32 MPA1 coils or 12 of 16 MPA2 coils can be switched on at the same time in the case of an MPA with CPI conne...

Page 33: ...position of the supply plates and separating seals can be freely selected with the valve terminal MPA Separating seals are integrated ex works as per your order Separating seals can be distinguished t...

Page 34: ...block with duct separation for operating with flat plate silencer or with ducted exhaust air Size Notes Pictorial examples Coding 1 2 I Duct 1 separate III Duct 1 and 3 5 separate H Note The duct sepa...

Page 35: ...82 84 are vented via the flat plate silencers Port 82 84 is tightly sealed Separating seals can be used optionally to create pressure zones Optional separating seal External pilot air supply flat plat...

Page 36: ...ly sealed Exhaust ports 3 5 and 82 84 are vented via the appropriate connec tions Separating seals can be used optionally to create pressure zones Optional separating seal External pilot air supply du...

Page 37: ...tion The diagram shows an example of the configuration and connection of three pressure zones using separating seals with external pilot air supply Zone 1 Zone 2 P1 Pilot air supply Zone 3 P2 P3 MPA w...

Page 38: ...1 Another way of creating pressure zones is to use manifold blocks with pressure zone separation The diagram opposite shows the version with pressure zone separation in duct 1 Zone 1 Zone 2 Pilot air...

Page 39: ...ction sizes MPA1 AI CI VMPA1 FB AP 4 1 T1 M7 QS4 QS6 Code I Separation in duct 1 in the manifold block AIII CIII VMPA1 FB AP 4 1 S1 Code III Separation in duct 1 and duct 3 5 in the manifold block B D...

Page 40: ...et by means of parameter settings You can parameterise the pressure sensor plate via the PLC or the handheld device CPXMMI from Festo Alternatively the pressure in the exhaust duct 3 5 and the process...

Page 41: ...osition based diagnostics Separate voltage supply for valves 2 4 valves Transmission of status parameter and diagnostic data There are different versions Without isolated electrical circuit VMPA FB EM...

Page 42: ...xhaust air Flat plate silencer 12 14 Pilot air supply Push in fitting QSM M7 6 I QSM M7 6 I M7 82 84 Pilot exhaust air Flat plate silencer Pressure compensation Vents into the atmosphere via silencer...

Page 43: ...ting brackets available Wall mounting Fieldbus connection The MPA valve terminal is screwed onto the mounting surface using six M4 or M6 screws The mounting holes are on the left hand end plate CPX an...

Page 44: ...e V can be fitted over the manual override to prevent it from being accidentally activated Pneumatic connection and control elements 1 4 2 3 1 Flat plate silencer for exhaust port 3 5 2 Manual overrid...

Page 45: ...kwise by 90 until the stop is reached Valve remains actuated 2 Turn the stem anti clockwise by 90 until the stop is reached and then remove the pin or screwdriver Spring force pushes the stem of the M...

Page 46: ...on the multi pin plug can actuate exactly one solenoid coil If of valve positions is 24 this means that 24 valves can be addressed with one solenoid coil With 12 or less valve positions 2 sole noid c...

Page 47: ...terminals and CP modules are connected using a ready to install CP cable and are attached to the CP interface Four modules for example one CPV valve terminal and one to three CP input modules make up...

Page 48: ...d 2 To IEC 757 Dimensions Download CAD data www festo com Connecting cable 1 Cable conduit fitting with clamping range 6 12 mm The wire colours refer to the following pre assembled multi pin cables fr...

Page 49: ...the NEBU modular product system Internet nebu Instructions for use Equipment Bio oils Mineral oils Operate your equipment with unlubri cated compressed air if possible Festo valves and cylinders are...

Page 50: ...g yp g On H rail to EN 60715 Mounting position Any Manual override Non detenting detenting blocked Width mm 10 5 21 Pneumatic connections Pneumatic connection Via manifold block or individual connecti...

Page 51: ...ture of medium C 5 50 Storage temperature1 C 20 40 Relative air humidity at 40 C 90 Corrosion resistance class CRC2 1 1 Long term storage 2 Corrosion resistance class 1 as per Festo standard 940 070 C...

Page 52: ...return MPA1 for valves with code NS KS HS DS Flow rate qn as a function of output pressure p2 with pressure regulator plates P regulator plate for port 1 Width 21 mm Supply pressure 10 bar set regula...

Page 53: ...pply pressure 10 bar set regulator pressure 6 bar Flow rate qn as a function of output pressure p2 with pressure regulator plates B regulator plates rev for ports 3 reversible Width 21 mm Supply press...

Page 54: ...l spring return 230 310 230 310 H 2x 3 2 way valve 1x normally open 1x normally closed 280 305 280 305 HS 2x 3 2 way valve 1x normally open 1x normally closed mechanical spring return 300 305 300 305...

Page 55: ...mes ms Valve function order code M J N K H B G E X W D I NS KS HS DS MPA1 Switching times on 10 10 10 10 10 10 10 10 10 10 10 10 14 14 14 14 g off 20 20 20 20 35 35 35 20 20 20 20 16 16 16 16 change o...

Page 56: ...reduction mA 9 18 Time until current reduction ms 24 24 Diagnostic message Undervoltage VOFF 3 V 17 5 16 Electrical data MPA with electronics module VMPA MPM AS interface multi pin plug Current consu...

Page 57: ...ions and shock for the CPX terminal 2 Valve terminal MPA with MPM connection and more than 5 manifold blocks Severity level 1 Valve terminal MPA with CPX terminal or MPM connection and up to 5 manifol...

Page 58: ...late Regulator plate Control section housing polyamide seals nitrile rubber Product weight Approx weight g MPA1 MPA2 Manifold block basic weight1 400 4 valve positions 400 2 valve positions Manifold b...

Page 59: ...ns Download CAD data www festo com MPA1 valve on individual sub base 1 Solenoid valve 2 Individual sub base 3 4x mounting holes for screw M3 4 Earthing screw MPA2 valve on individual sub base 1 Soleno...

Page 60: ...festo com Valve terminal with multi pin plug connection 1 Solenoid valve MPA1 2 Solenoid valve MPA2 3 Manual override 4 Supply exhaust ports 5 Working lines 6 H rail 7 H rail mounting 8 Mounting holes...

Page 61: ...CAD data www festo com Valve terminal with AS interface connection 1 Solenoid valve MPA1 2 Solenoid valve MPA2 3 Manual override 4 Supply exhaust ports 5 Working lines 6 H rail 7 H rail mounting 8 Mo...

Page 62: ...nection 1 Solenoid valve MPA1 2 Solenoid valve MPA2 3 Manual override 4 Supply exhaust ports 5 Working lines 6 H rail 7 H rail mounting 8 Mounting holes 9 Manifold block aJ Earthing screw aA Electrica...

Page 63: ...d valve MPA1 2 Solenoid valve MPA2 3 Manual override 4 Supply exhaust ports 5 Working lines 6 H rail 7 H rail mounting 8 Mounting holes 9 Pneumatic interface MPA aJ CPX module aA Earthing screw aB Ele...

Page 64: ...on Any Reset method Mechanical spring Pneumatic connection 1 2 3 Manifold block Nominal diameter Pressurisation mm 6 Exhaust mm 4 5 Standard nominal flow rate 2 bar type l min 380 6 bar type l min 900...

Page 65: ...nical data Proportional pressure regulator VPPM Flow rate qn from 1 2 as a function of output pressure p2 VPPM 6TA 0L2H 2 bar VPPM 6TA 0L6H 6 bar VPPM 6TA 0L10H 10 bar Flow rate qn from 2 3 as a funct...

Page 66: ...ype S1 1 Repetition accuracy FS full scale 0 5 Temperature coefficient K 0 04 Ambient temperature C 0 60 Temperature of medium C 10 50 Corrosion resistance class CRC1 2 CE mark see declaration of conf...

Page 67: ...F 0L2H S1 542217 QB 2 0 8 0 06 6 VPPM 6TA L 1 F 0L6H 542221 QE 1 VPPM 6TA L 1 F 0L6H S1 542218 QC 2 0 11 0 1 10 VPPM 6TA L 1 F 0L10H 542222 QF 1 VPPM 6TA L 1 F 0L10H S1 542219 Ordering data Accessorie...

Page 68: ...lly closed VMPA2 M1H D Gx PI 537971 I 2x 2 2 way valve 1x normally closed VMPA1 M1H I M7 PI 545230 1x normally closed 1 x normally closed reversible VMPA2 M1H I Gx PI 545232 External pilot air MS 5 2...

Page 69: ...closed mechanical spring return VMPA1 M1H KS PI 556838 H 2x 3 2 way valve 1x normally open VMPA1 M1H H PI 533349 1x normally open 1x normally closed VMPA2 M1H H PI 537959 HS 2x 3 2 way valve 1x norma...

Page 70: ...R3C2 C 06 549057 PN MPA2 connection 2 reversible VMPA2 B8 R6C2 C 06 549113 PM MPA2 connection 4 reversible VMPA2 B8 R7C2 C 06 549114 Pressure gauge for regulator plate With cartridge connection for r...

Page 71: ...ositions MPA2 VMPA2 FB AP 2 1 S0 555902 Manifold blocks incl electrical manifold module and electronics module For fieldbus Four valve positions MPA1 VMPA1 AP 4 1 EMS 8 546802 Two valve positions MPA2...

Page 72: ...haust air VMPA ASI EPL G 4E4A Z 546989 p p p Silencer VMPA ASI EPL GU 4E4A Z 546991 External pilot air Ducted exhaust air VMPA ASI EPL E 4E4A Z 546988 p Silencer VMPA ASI EPL EU 4E4A Z 546990 8 inputs...

Page 73: ...lated electrical circuit with expanded diagnostics function 8 coils MPA1 VMPA1 FB EMG D2 8 543333 For modular multi pin plug connection MPM 2 coils MPA2 VMPA2 MPM EMM 2 537985 p p g 4 coils MPA2 VMPA2...

Page 74: ...pieces VMPA HBT B 540897 Cover for manual override covered 10 pieces VMPA HBV B 540898 Seals for manifold block MPA with ducted exhaust air No duct separation VMPA1 DP 533359 Duct 1 separate VMPA1 DP...

Page 75: ...S2 24 10 PUR 533503 Connecting cable individual connection Plug socket with cable straight socket 2 5 m SIM M8 4GD 2 5 PU 158960 5 m SIM M8 4GD 5 PU 158961 Plug socket with cable angled socket 2 5 m S...

Page 76: ...ad G for tubing O D 8 mm 10 pieces QS G 8 I 186110 g g 10 mm 10 pieces QS G 10 I 186112 Silencer Connecting thread M5 UC M5 165003 g M7 UC M7 161418 G UC 165004 Gx UC x 161419 Push in sleeve connectio...

Page 77: ...A FR 534243 Spanish P BE MPA ES 534242 Italian P BE MPA IT 534244 Swedish P BE MPA SV 534245 MPA electronic description German P BE MPA Elektronik DE 562112 p Pneumatic modules pressure sensor proport...

Page 78: ...ny liability for resulting damages You should contact Festo s advisors if one of the following apply to your application The ambient conditions and condi tions of use or the operating me dium differ f...

Reviews: