5
ELECTRIC CONNECTION
The cooling cabinet /freezer is connected
to the electric socket (single phase, 230V,
50 Hz) using the connecting lead of the
appliance. The fuse size for the socket is
10 A. Any alterations to the connection
method or changing of the connecting
lead must only be done by an electrician.
A suitable place for the socket is in the
back wall at the location of the cooling ca-
binet /freezer, at a height of 2060 mm
from the floor to the lower edge of the
socket.
The socket can also be situated at a cor-
responding place in the ceiling, at a maxi-
mum of 500 mm from the back wall.
Any excess length of connecting lead
must not be pushed into the back cavity,
but must be left on top of the cooling cabi-
net /freezer.
If this appliance is situated in the corner, it
has to be done so that the door is able to
open enough (see the picture).
Do not situate the appliance in a small,
poorly ventilated place. Faultless operati-
on of the mechanism requires good venti-
lation. The air inlet at the front of the app-
liance, below the door, must not be cove-
red.
AN AIR CIRCULATION GAP OF 40 mm
MUST BE LEFT ABOVE THE APPLIAN-
CE (see operational description / air cir-
culation, page 8, picture).
The floor where the appliance is situated
must be even and horizontal, and at the
same level as the surrounding floor.
In the cooling cabinet, ice formed on the
expansion coil melts automatically and the
resulting water is conducted to the evapo-
ration trough in the compressor area,
from which it evaporates automatically.
If there will be any functional disorder it is
possible that there will be water leakage
under the appliance.
That is why we recommend to install a
protective cover to the floor where the
appliance will be situated.
The floor cover can also be ordered from
Festivo-service.
The refrigerator-freezer combination can
be situated against the background surfa-
ce and side surfaces, but if the side surfa-
ce comes next to another cold storage
appliance or an outside wall, then a venti-
lation gap of at least 1 cm must be left bet-
ween the surfaces concerned.
No other appliances or furniture must be
fixed to the appliance, because it has to
be possible to pull it out for cleaning and
servicing.
min.50 mm
7
50
745
58
8
Distance
from the wall