8 COMMISSIONING
8.1 Powering on/Connecting the Device
To power the device, you must have an appropriate power cable that
takes voltage (24 V AC) from the machine tool itself.
Characteristics of the power cord:
2 X
0.75 mm
2
.
For proper connection of the power cord use insulated terminals:
Figure 4 - Power supply
Connection
Check that the cables are properly connected. In the event of connection difficulties contact
an electrician.
8.2 Installation
Install the lamp on the structure and/or on the frame of the machine tool, near the area that
is to be illuminated, using bolts and nuts to clamp it into place. To do this, drill four holes on
the machine (if not already present) arranged on the vertices of a square with 60 mm sides.
Insert the bolts into the holes on the pedestal and the ones on the machine, respectively, and
tighten the nuts to ensure that they are strong and securely fastened.
I
DEAL AND INCORRECT POSITIONS FOR PROPERLY ILLUMINATING THE WORK AREA OF THE MACHINE
TOOLS
.
Figure 5 – Mounting positions of the lamps for machine tools.
The lights must be mounted in order to:
Provide the illumination required in the work area for moving parts;
Do not allow the lamp to interfere with the duties of the operator or blind the operator;
Minimize the accumulation of dirt on the lamps and spotlights;
Facilitate maintenance.