8
MACHINE SAFETY DEVICES
8.1 Electrical safety devices
The control device inserted in the electrical circuit of the Portable chamfering machine is a
magnetic switch
with two buttons (see chapter 6 of this manual). This prevents the danger
of unwanted and/or accidental starts of the machine, since the switch can only be activated
through a voluntary action suitable for the given purpose and when the machine is powered.
If power is restored following an unintentional power cut, the machine does not start by itself
but must be turned on with the normal start button.
Furthermore, the start button is equipped with a protective collar.
In the event of malfunction or breakdown, the Portable chamfering machine is equipped with
power cable and plug with
grounding conductor
, which provides a path of least resistance
for electric current and reduces the risk of electric shock.
The plug must be plugged into an appropriate socket, grounded in accordance with current
regulation. Extension cables must be of a section equal to or greater than the power cable of
the machine.
Electric Shock
Improper connection of the machine’s grounding conductor can result in the risk of electric
shock.
It is necessary to connect the machine to an electrical system that has a device for the
automatic interruption of the power supply in case of failure, which is consistent with the
protections installed on the machine. For more detailed information, contact a trusted
electrician.
Check with a qualified electrician if you don't understand the grounding instructions
or if you have any doubts about grounding the machine.
fervi.com