9
USE - REMOTE CONTROL
Timer activation
("Select", + and - buttons)
With the
+
or – buttons select the function
TIMER ON (indicated by the Black icon on the display)
or
TIMER OFF (indicated by the White icon on the display) .
press
“On/Send”
to send the information to the thermostat.
The unit will only emit a “beep”, when the signals are received correctly.
The Yellow LED will light up on the display with the indication TIMER.
IMPORTANT: If no button is pressed for 10 seconds the normal
display is automatically restored.
Fig. 4
Start / Stop
("Select", + and - buttons)
procedure for setting switching on time
1.
To activate the procedure for setting the switching On/Off times,
press the Select button twice in quick succession.
2.
The pROGRAM START
symbol will start flashing on the display.
3.
To adjust the hours use the
+
or - buttons.
4.
To confirm the required hour press the Select button.
5.
To adjust the minutes use the
+
or - buttons.
6.
To confirm the required minutes press the Select.
7.
The pROGRAM STOp
symbol will start flashing on the display.
8.
To adjust the hours use the
+
or - buttons.
9.
To confirm the required hour press the Select button.
10. To adjust the minutes use the
+
or - buttons.
11. To confirm the required minutes press the Select button.
12. The TIMER
symbol will start flashing on the display.