7
4. Cleaning
Cleaning the fireplace should be done only when cold. The cleaning of the combustion chamber
must be carried out daily. For this purpose, make sure the fireplace has ceased operation and is
completely cold. Pull up the combustion pot and remove it from the stove and then clean it from
soot. When removed fuel pot at the bottom of the combustion chamber opens a hole designed for
the accumulated ash. Collect ashes in the ashtray and return fuel pot in place and then close the
door. The fireplace is ready for operation.
Cleaning of flues and chimneys are conducted once every 1.5 tons of fuel used
Once clean audits and close the cleaning lid. Check that the bolts are tightened well. Every time
you open check for violations of the isolation seal. If this happens do not use the product until the
isolation seal is repaired.
1
2
Manual system for
cleaning the
turbulators
Automatic
combustion
chamber cleaning