Ferroli SALERNO PELLET Assembly And Exploitation Manual Download Page 17

17

The main frame shows: 

time and date, chrono activation, combustion 

power and recipe, functioning state, error code, 

main temperature, main thermostat, 

summer/winter mode.

Button 

Function 

P1 

P2 

P3 

P4 

P5

 

P6

 

Exit Menu/Submenu;
Ignition and extinguishing (push for 3 seconds), Reset errors (push for 3 seconds), Enable/disable chrono;
Enter in User Menu 1/submenu, Enter in User Menu 2 (push for 3 seconds), Save data;
Enter in Visualizations Menu, Increase
Activation chrono time band
Enter in Visualizations Menu, Decrease

Led

 

Function 

D1 

D9 

D2 

D10 

D3 

D11 

D5 

D12 

Auger ON

V2: Pump 1 ON

R: Igniter ON 

Aux2: Pump 2 ON 

External Chrono reached

Lack of pellet

Local Room Thermostat reached

Sanitary water demand

Er01 

- Security Error High Voltage 1. It may also intervene with the system off;

Er02 

- Security Error High Voltage 2. It can only intervene if the Combustion fan is active;

Er03 

- Extinguishing for low exhaust temperature or missing light in the brazier;

Er04 

- Extinguishing for water over temperature;

Er05 

- Extinguishing due to high exhaust temperature;

Er06 

- Pellet Thermostat open (flame return from the brazier);

Er07 

- Encoder Error. The error may occur due to lack signal from Encoder;

Er08 

- Encoder Error. The error can occur due to problems of adjustment of the number of revolutions;

Er09 

- Water pressure low;

Er10 

- Water pressure high;

Er11 

- Clock Error. The error occurs due to problems with the internal clock;

Er12 

- Extinguishing for ignition failure;

Er15 

- Extinguishing due to power failure for more than 50 minutes;

Er16 

- RS485 communication error (Display);

Er17 

- Adjusting the Air Flow Failed;

Er18 

- No more Pellet in the bunker;

Er23 

- Boiler probe or Back boiler probe or probe Buffer open;

Er25 

- Engine cleaning brazier broken;

Er26 

- Engine cleaning broken;

Er27 

- Engine cleaning 2 broken;

Er34 

- Depression below the minimum threshold;

Er35 

- Depression above the maximum threshold;

Er39 

- Sensor Flowmeter broken;

Er41 

- Minimum air flow in Check Up is not reached;

Er42 

- Maximum air flow exceeded;

Er44 

- Open door error;

Er47 

- Error Encoder Auger: missing signal Encoder;

Er48 

- Error Encoder Auger: Auger regulation speed not achieved;

Er52 

- Error Module I/O I2C; 

Er57 

- Test ’Forced Draught High’ in Check Up fail ;

Service 

- Service error. It notifies that the planned hours of functioning is reached. It is necessary to call for service.

ALARMS

CONTROL PANEL: USE AND FUNCTIONS

Chrono Active Date and Time State

Error Code

Main Thermostat

Main Temperature

Recipe. Power

Comb. Power

P1

P2

P3

P4

P5

P6

Description

 

Code 

Sond

Hi

Clean

Port

Ignition 

block

Cleaning on

Link Error

Anomaly of the probes checking, during Check Up phase.
Room temperature greater than 99 °C.
This message notifies that the planned hours of functioning are reached.
Door Open.

The message appears if the system is turned off during Ignition (after Preload) not manually: 

the system will stop only when it goes in Run Mode.

Periodical Cleaning in progress.
No communication between motherboard and keyboard

MESSAGES

Exhaust T. [°C]

  - Exhaust temperature;

Room T. [°C]

  - Local room temperature; it is visible only if;

Buffer T. [°C]

 - Buffer Temperature;

Pressure [mbar]

 - Water pressure;

Air Flux

 - Air flow;

Fan Speed [rpm]

 - Exhaust fan speed;

Auger [s]

 - Auger work time;

Recipe [nr]

 - Combustion recipe set;

Product Code: 510

 - Product code;

VISUALIZATIONS

USER MENU 1

Combustion Management

Power - 

In this menu is possible to modify the combustion power of the system. It can be set in automatic or 

manual modality . In the first case the system chooses the combustion power. In the second case the user selects 

the desired power. On the left side of the display are signalled the combustion modality (A=automatic combustion, 

M=manual combustion) and the working power of the system.

Recipe 

- Menu to select the combustion recipe. The maximum value is the number of recipes visible to the user. 

Auger Calibration - 

It allows to modify the value set in firm of Auger’s speed or On times. The values are in the 

range – 7 ÷ 7. The firm’s value is 0.

Fan Calibration - 

It allows to modify the value set in firm of Combustion Fan’s speed. The values are in the range 

– 7 ÷ 7. The firm’s value is 0.

Heating Management
Boiler thermostat 

- Menu to change the value of the boiler thermostat .

Buffer thermostat - 

Menu to change the value of the Buffer Thermostat.

Room Thermostat - 

This Menu allows to modify the Local Room Thermostat’s value. It is visible only if the ambient 

probe is select.

Summer-Winter -

 Menu that allows the selection Summer-Winter.

Manual Load

The procedure activates the pellet manual loading with activation in continue modality of the Auger engine. The 

loading is stopped automatically after 600 seconds. The system must be OFF for the function can be activated.

Cleaning Reset

 

Menu to reset the ‘System Maintenance 2’ function.

Summary of Contents for SALERNO PELLET

Page 1: ...SALERNO PELLET Pellet stove Assembly and exploitation manual ...

Page 2: ...behaviouroromissions Anyinterventionorreplacementthatismadebyunauthorizedpeopleorusingnonoriginalspareparts fortheproductcanberiskyfortheuserandreleasethecompanyfromallliability Most surfaces of the stove are extremely hot the door handle glass flue pipe etc Avoid contact with thesepartsbeforeassuringyourselfthatyouustemperatureresistantglovesaswellassuitabletemperature resistantinstruments Undern...

Page 3: ... by compressed wooden waste left from the production of various furni ture sawmills and others This type of fuel is environmentally friendly because in the production process no agglutinate agents glues resins and others are added Actually the integrity of the pellets is guaranteed by the lignite a natural ingredient contained in the wood itself While the wood has a calorie capacity of 4 4 kW kg 1...

Page 4: ...ray must be done only when the stove is cold SALERNO PELLET Maximum minimum power kW 12 00 3 90 18 00 6 00 24 00 7 50 30 00 14 00 Average consumption of pellets kg h 1 6 2 4 3 2 3 9 Efficiency nominal reduced 95 95 94 95 94 95 93 93 Temperature of the flue gas ºC 91 79 129 79 131 82 108 93 Co Emissions 13 O mg Nm 128 96 97 262 The chimney draft Pa 12 12 12 12 Exhaust gas pipe Φmm 80 80 80 80 Elect...

Page 5: ... with water serpentine and a solar panel For economy and efficiency of the system and a constant availability of cheap hot water a qualified assembly of the automatic shifter controlling the thermal flows to and out of the solar panel and the stove is required Chart 2 shows a one storey heating with a compulsory circulation The advantage of this chart is that the water conducting elements can be h...

Page 6: ...replace is installed The duct components must allow a soot cleaning The duct components must have a constant section A section change is allowed only in the chimney joint Chimney The chimney or the duct component must conform with the following requirements to be air tight waterproof and properly insulated to be constructed with materials resistant to the normal mechanical wear and to the heat com...

Page 7: ...amber opens a hole designed for the accumulated ash Collect ashes in the ashtray and return fuel pot in place and then close the door The fireplace is ready for operation Cleaning of flues and chimneys are conducted once every 1 5 tons of fuel used Once clean audits and close the cleaning lid Check that the bolts are tightened well Every time you open check for violations of the isolation seal If ...

Page 8: ...ent uses the manual cleaning mechanism the ash will drop to the ashtray in the combustion chamber as well as in the service chamber that is located beneath Service compartment Ash container Cleaning the pellet bunker ...

Page 9: ...9 6 5 4 2 1 DHW PUMP 2 PUMP COLD WATER 3 SAFETY VALVE 4 HOT WATER 1 3 7 8 5 EXHAUST FAN 6 POWER SUPPLY 7 AIR INTAKE PIPE 8 KEY FOR CLEANING MECH ANISM OF THE TURBULA TORS ...

Page 10: ...ireplace may fall hot burning particles as hot ash and small particles burning coal which could lead to a fire in the heated room It is therefore necessary that the product always works with a tightly closed door It can only be opened when the product has completely cooled down Risks of burns caused by high temperatures as a result of the combustion process in the combustion chamber and or access ...

Page 11: ... K400 TOUCH SCREEN DISPLAY 1 HOMEPAGE Errors Code Date Time HOMEPAGE 1 2 Main Temperature Main Thermostat Functioning State ON OFF Settings Display Info Chrono 11 24 Fri 14 Oct 2016 65 21 C IGNITION Er 01 ...

Page 12: ... Aux1 Pump 1 Aux1 Pump 2 Aux3 HOMEPAGE 2 2 L6 L7 L8 System activity LEDS The Quick visualization of the system main function is accessed through a vertical swipe to the top side of the screen SPECIAL LEDS 65 22 C IGNITION 12 18 Ven 14 Ott 2016 Er52 Function Winter Mode Power Chrono Wood PA Weekly Winter Wood Pellet Pellet Wood Chrono enable Chrono disable Summer ...

Page 13: ...6 65 21 C IGNITION Er 01 Er10 10 50 11 20 11 20 11 20 11 20 Er 53 Er 53 Er 53 Er 53 Error List By clicking on you can see the errors stored by date time and description Scroll to unlock Error 16 Auger speed regulation failure When this message is on screen this means that the product is in blocking mode and you can remove the error You can do this by swiping to the right in the center of the scree...

Page 14: ...personnel Settings Menu 12 18 Ven 14 Ott 2016 28 22 C RECUPERO ACCENSIONE Er52 COMBUSTION HEATING REMOTE PANEL MANUAL LOADING RESET SERVICE Setting Menu 11 24 Ven 14 Ott 2016 65 C IGNITION Er 01 From this screen it is possible to view all the variables for the proper functioning of the heating system Info Menu Water Pressure Smoke Temperature Boiler Temperature Buffer Temperature Oxygen Exhaust pr...

Page 15: ... 30 00 45 15 02 03 05 04 06 00 15 45 30 00 To edit the time slots press on the corresponding Frame Time Scroll Up or Down to change the System on off Time 5 INTERNAL MENU STRUCTURE Potenza Pellet 5 5 5 5 Ricetta Pellet Calibrazione Coclea Calibrazione Ventilatore Gestione Combustione Pellet Recipe Boiler Thermostat 5 50 80 65 63 64 66 67 Potenza Pellet 5 5 5 5 Ricetta Pellet Calibrazione Coclea Ca...

Page 16: ... panel is 17 and subsequently the others according to the number provided by the system Control panel restart this function allows the control panel to be restarted Sound this function allows the user to enable disable the sounds emitted from the control panel Delete error list this password protected function the same as in the technical menu allows the user to delete the list of errors recorded ...

Page 17: ... is reached It is necessary to call for service ALARMS CONTROL PANEL USE AND FUNCTIONS ChronoActive DateandTime State ErrorCode MainThermostat MainTemperature Recipe Power Comb Power P1 P2 P3 P4 P5 P6 Description Code Sond Hi Clean Port Ignition block Cleaning on Link Error Anomaly of the probes checking during Check Up phase Room temperature greater than 99 C This message notifies that the planne...

Page 18: ...S9 GND S10 S11 Vc V IN 9 IN 10 11 POWER CABLE COMBUSTION FAN PUMP 1 IGNITER PRESSURE SWITCH MOTOR FOR CLEANING MECHANISM THREE WAY VALVE OR PUMP 2 DISPLAY EXHAUST PROBE ROOM THERMOSTAT BOILER PROBE BUFFER PROBE PROGRAMMER RELAY FOR THE CLEANING MECHANISM SIGNAL KEY FOR CLEANING MECHANISM GND VOUT V FAN ENCODER GND V VOUT F U S E SAFETY AUGER 2 3 4 47 46 AUX 3 COM N O WATER OVERHEATING PROTECTION P...

Page 19: ......

Page 20: ...bility for possible inaccuracies contained in this manual if they are due to printing or transcription errors We reserve the right to make any change that appears to be necessary or useful without harm the essential characteristics ...

Reviews: