19
OPTIMAX HE PLUS S
Cod. 3540R543 - 08/2012 (Rev. 00)
Condensate drain
If possible, the condensate should be conveyed inside the internal drainage system or pipe. For that purpose, use a
pipe of at least 22 mm diameter and a trap with
fl
exible connection supplied with the unit to facilitate connection of the
condensate drain pipe.
The pipe must be in glue-joined plastic and not in copper, since the condensate has a pH of 4 (slightly acid).
If the condensate drain pipe cannot be ended on the inside, it is advisable to run it outside as shown in the following
fi
gure.
The pipe sections going to the outside are exposed to the risk of freezing in particularly extreme weather conditions. To
prevent this from occurring, it is advisable to reduce the length of the condensate drain pipes and run them on the inside,
as much as possible, before going to the outside. It may also be necessary to insulate the condensate pipe or apply a
trace heating device to prevent freezing of the condensate.
The pipes outside the building must be in glue-joined plastic with increased diameter of up to 32 or 40 mm with a maximum
run of 3m for connection to a condensate collection soakaway or external drain.
If using a condensate collection soakaway, it must be as indicated in the
fi
gure below, or use a speci
fi
c system (such
as Mc Alpine SOAK1GR) available from the majority of suppliers of products and accessories for plumbing or heating
systems.
Fyufsobm
43051nn!Tpmwfou!xfme!qjqfxpsl!3/6!+!Njojnvn!Gbmm!tff!cfmpx
Dfnfou!tfbm
211nn!Ejb!uvcf
Cpuupn!tfbmfe
Mjnf!tupof!dijqqjoht
Hspvoe!mfwfm!)fjuifs0Ps*
Ipmf!efqui!511nn
36nn
3!Spxt!pg
4y23!nn!Ipmft
Joufsobm
.411nn
fi
g. 22 - Condensate drain