7 TROUBLESHOOTING
7.1 Alarm management
Alarms are indicated by an acoustic signal (if activated) and a message on the control panel.
In case of an alarm, shut down the boiler, eliminate the cause and restart the boiler according to the normal
procedure described in this manual.
Every alarm status causes immediate boiler shutdown.
The alarms, with causes and cures, which can appear on the control panel are listed below:
ALARMS - MESSAGES
Signalling
Fault
Possible causes
Cures
AL 1
POWER
FAILURE
-The boiler does not start.
-No power during the lighting
stage.
-Turn the boiler OFF by
pressing the button P4 and
repeat the lighting procedure.
-Other reinstatement
operations must be carried
out by a service centre.
AL 2
FUME
PROBE
-Occurs in case of a fume
temperature probe fault.
-The shutdown procedure is
activated.
-Probe fault.
-The probe is disconnected
from the board.
-Reinstatement operations
must be carried out by a
service centre.
AL 3
HOT FUMES
-Occurs if the fume probe
detects a fume temperature
above 280°C.
-The shutdown procedure is
activated.
-Too many pellets.
-Reduced heat exchange
in the system.
-Adjust the pellet flow.
-Other reinstatement
operations must be carried out
by a service centre.
AL 4
FAN FAIL
-Occurs when the fume
extraction fan is faulty.
-The shutdown procedure is
activated.
-The fume fan is blocked.
-Faulty speed control sensor.
-No power to fume fan.
-Reinstatement operations
must be carried out by a
service centre.
AL 5
NO IGNITION
-No flame in ignition stage.
-The shutdown procedure is
activated.
-The pellet hopper is empty.
-The heater is faulty, dirty or not
correctly positioned.
-Pellet load setting incorrect.
-Check pellets in hopper.
-Check the lighting
procedures.
-Other reinstatement
operations must be carried
out by a service centre.
AL 6
NO PELLETS
- Brazier not fed with pellets.
-The pellet hopper is empty.
-The pellet loading gearmotor
has to adjust.
-The gearmotor does not load
pellets.
-Check pellets in hopper.
-Adjust the pellet flow
-Other reinstatement
operations must be carried
out by a service centre.
AL 7
THERMAL
SAF
-Occurs in case of cutting in of
the auger duct temperature
safety thermostat.
-The system is stopped.
-The safety thermostat has
detected a temperature above
the setting threshold due to
overheating of the bottom part
of the hopper blocking
gearmotor operation.
-Check the cause of excessive
overheating.
-Reset the relevant safety
thermostat by pressing the
reset button.
AL 8
NO NEG
PRESS
-
In the work stage the boiler
detects a pressure below the
vacuum switch setting
threshold.
-The system is stopped.
-
The combustion chamber is dirty.
-The fume duct is obstructed.
-The fire door is not closed.
-The overpressure valves are
open-stuck.
-Faulty vacuum switch.
-Check cleanness of the fume duct
and combustion chamber.
-Check hermetic closing of the door.
-Check closing of the overpressure
valves.
-Other reinstatement operations must
be carried out by a service centre.
Summary of Contents for NATURFIRE 30 HR
Page 2: ...NATURFIRE 30 35 39 HR 2...
Page 3: ...NATURFIRE 30 35 39 HR 3...
Page 5: ...NATURFIRE 30 35 39 HR 5...
Page 6: ...NATURFIRE 30 35 39 HR 6...
Page 7: ...NATURFIRE 30 35 39 HR 7...
Page 8: ...NATURFIRE 30 35 39 HR 8...
Page 19: ...NATURFIRE 30 35 39 HR 19 2 7 Schema elettrico...
Page 49: ...NATURFIRE 30 35 39 HR 49 2 7 Wiring diagram...
Page 80: ...NATURFIRE 30 35 39 HR 80 2 7 Sch ma lectrique...
Page 111: ...NATURFIRE 30 35 39 HR 111 2 7 Elektroschaltplan...
Page 142: ...NATURFIRE 30 35 39 HR 142 2 7 Esquema el ctrico...