“In” - Information Menu
The regulator can display the following information:
Press the Up/Down buttons to scroll the list of information. To display the value just press the Enter button in relation to
the parameter . In case of damaged Sensor, the regulator displays hyphens .
Press the Enter button to return to the list of information .
Press the Info button to return to the Service Menu . Press the Info button for 10 seconds to exit the regulator Service
Menu or exiting is automatic after 15 minutes .
“Hi” - History Menu
The microprocessor can memorise the total hours with regulator fed (Ht), the last 10 boiler faults and other information
; the History datum item H1: represents the most recent fault that occurred; the History datum item H10: represents the
least recent fault that occurred.
Press the Up/Down buttons to scroll the list of faults . To display the value press the Enter button in relation to the parameter .
Press the Enter button to return to the list of faults .
Press the Info button to return to the Service Menu . Press the Info button for 10 seconds to exit the card Service Menu
or exiting is automatic after 15 minutes .
t01
S1: PT1000 sensor - Not used (°C)
--
t02
S2: Hot water tank NTC sensor (°C)
Only with parameter P26=1, Stand alone
--
t03
S3: Solar collector PT1000 sensor (°C)
between 01 and 175°C
t04
S4: Solar Return Collector NTC sensor (°C)
between 01 and 125°C
F05
Solar circuit flow rate (Lt_min)Only with Flowmeter connected and activated
00-99 Lt_min
P06
Actual modulating circulating pump speed (40%=Speed 1¸ 100%=Speed 5)
0-100%
Ht
No. hours ECOTRONIC Tech operation (Supply)
between 0 and 9999 hours
H01
Fault code
H02
Fault code
H03
Fault code
H04
Fault code
H05
Fault code
H06
Fault code
H07
Fault code
H08
Fault code
H09
Fault code
H10
Fault code
H11
No. hours Solar Circulating Pump operation
between 0 and 9999 hours
H12
No. hours AUX1 output relay operation
between 0 and 9999 hours
H13
No. hours AUX2 output relay operation
between 0 and 9999 hours
H14
No. hours FREE CONTACT output relay operation
between 0 and 9999 hours
H15
Max. temp. S1: PT1000 sensor Not used (°C)
--
H16
Max. temp. S2: Hot water tank NTC sensor (°C) Only with parameter P26=1, Stand alone
--
H17
Max. temp. S3: Solar Collector PT1000 sensor (°C)
between 01 and 175°C
H18
Max. temp. S4: Solar Return Collector NTC sensor (°C)
between 01 and 125°C
H19
No. litres solar circuit (litres)Only with Flowmeter connected and activated
between 0 and 9999 litres
H20
Average circulating pump speed (%)Cumulative calculation performed only if the circulating
pump is working
0-100%
BIL
Thermal quantity balance (KWh)Cumulative calculation performed only if the circulating pump
is working
between 0 and 9999 kWh