Gas supply conversion
The unit can function with either Natural Gas or LPG and is factory-set for use with one of the two gases,
as clearly shown on the packing and on the units dataplate. Whenever a different gas to that for which the
unit is preset has to be used, a conversion kit will be required, proceeding as follows:
1
Replace the nozzles at the main burner, inserting the nozzles specified in the technical data table,
according to the type of gas used.
2
Adjust the burner minimum and maximum
pressures, setting the values given in the
technical data chart for the type of gas
used.
3
Move the jumper JP02 on the card, as
shown in the diagram:
4
Apply the sticker, contained in the
conversion kit, near the dataplate as
proof of the conversion.