DIVAtech F 32 D
39
(1
cod. 3541A770 -
10
/2011 (Rev. 00)
5.3 Technical data table
5.4 Diagrams
Pressure - power diagrams
A
LPG
B
NATURAL GAS
Circulating pump head / pressure losses
A
Boiler pressure losses
1 - 2 - 3
Circulating pump speed
Data
Unit
DIVAtech F 32 D
Max. heating capacity
kW
34.4
(Q)
Min. heating capacity
kW
11.5
(Q)
Max. Heat Output in heating
kW
32.0
(P)
Min. Heat Output in heating
kW
9.9
(P)
Max. Heat Output in hot water production
kW
32.0
Min. Heat Output in hot water production
kW
9.9
Efficiency Pmax (80-60°C)
%
93.1
Efficiency 30%
%
91.0
Efficiency class Directive 92/42 EEC
-
NOx emission class
-
3 (<150 mg/kWh)
(NOx)
Burner nozzles G20
n° x Ø
15 x 1.35
Gas supply pressure G20
mbar
20.0
Max. gas pressure at burner (G20)
mbar
12.0
Min. gas pressure at burner (G20)
mbar
1.5
Max. gas delivery G20
m
3
/h
3.64
Min. gas delivery G20
m
3
/h
1.22
Burner nozzles G31
n° x Ø
15 x 0.79
Gas supply pressure G31
mbar
37
Max. gas pressure at burner (G31)
mbar
35.0
Min. gas pressure at burner (G31)
mbar
5.0
Max. gas delivery G31
kg/h
2.69
Min. gas delivery G31
kg/h
0.90
Max. working pressure in heating
bar
3
(PMS)
Min. working pressure in heating
bar
0.8
Max. heating temperature
°C
90
(tmax)
Heating water content
litri
1.2
Heating expansion tank capacity
litri
10
Heating expansion tank prefilling pressure
bar
1
Max. working pressure in hot water production
bar
9
(PMW)
Min. working pressure in hot water production
bar
0.25
DHW flow rate Dt 25°C
l/min
18.3
DHW flow rate Dt 30°C
l/min
15.2
(D)
Protection rating
IP
X5D
Power supply voltage
V/Hz
230V/50Hz
Electrical power input
W
135
Electrical power input in hot water production
W
135
Empty weight
kg
35
Type of unit
C
12
-C
22
-C
32
-C
42
-C
52
-C
62
-C
72
-C
82
-B
22
PIN CE
0461BR0842
A
B
0
1
2
3
4
5
6
7
0
500
1.000
1.500
2.000
Q
[l/h]
H
[m H
2
O]
A
3
1
2
Summary of Contents for DIVAtech F 32D
Page 31: ......
Page 79: ......
Page 80: ...FERROLI S p A Via Ritonda 78 a 37047 San Bonifacio Verona ITALY www ferroli it ...