Step 1 Remove boiler  outer case and lower control box.
Step 2 Remove control box cover.
Step 3 Connect brown and blue JST plug onto PCB terminal block X2.

Step 4 Connect brown and blue onto receiver terminals 1 and 2. Make 

sure live is connected to terminal 1. (the wire colour is not 
conclusive of polarity)
.

Step 5 Connect the two grey wires to terminal 3 and 4 on the receiver. On

the main boiler terminal block remove link wire from terminals 5 
and 6 and connect the two grey wires.

Step 6 Place receiver on back of terminal block cover and mark two

diagonally opposed fixing holes, with the cover removed drill two 
2.2mm holes. Mount the receiver using the shortest two screws 
supplied with the radio thermostat.

8

Summary of Contents for 30800013

Page 1: ...Suitable for all Ferroli Combination Boilers Radio Thermostat Mechanical Clock Part Number 30800013 Installation User Instructions...

Page 2: ...s Page No 3 Short Description 3 Safety Instructions 4 8 Receiver Installation 9 10 Installation Continued 11 Setting The Time 12 Set Heating ON OFF Periods 13 Set Max Min Room Temperatures 13 Manual S...

Page 3: ...Thermostat Mechanical Clock receiver the Radio Thermostat Mechanical Clock transmitter creates a room thermostat clock of highly advanced technology The device is wireless and controls the heating boi...

Page 4: ...nal 2 Switching wires Terminals 3 4 Please note If replacing universal digital timer please ensure you now use terminals 3 4 instead of 3 5 as per universal digital timer If wired incorrectly controll...

Page 5: ...terminal block Radio Thermostat Clock Receiver Universal Digital Clock 4 3 2 1 5 3 2 1 Step 1 Remove clock from control panel Step 2 Swap wiring as shown Make sure Live is connected to terminal 1 wir...

Page 6: ...tat clock is going to replace the existing room thermostat this must be linked out on the room thermostat terminal block Radio Thermostat Clock Receiver Universal Digital Clock 4 3 2 1 5 3 2 1 Step 1...

Page 7: ...is connected to terminal 1 Step 5 Connect the two grey wires to terminal 3 and 4 on the receiver On the main boiler terminal block remove link wire from terminals 4 and 5 and connect the two grey wir...

Page 8: ...terminal 1 the wire colour is not conclusive of polarity Step 5 Connect the two grey wires to terminal 3 and 4 on the receiver On the main boiler terminal block remove link wire from terminals 5 and 6...

Page 9: ...ode heating for 4 min and off for 9 min Ensure the batteries are ok replace batteries if necessary Radio link installation 1 Press receiver button and hold down for 2 seconds The LED flashes twice The...

Page 10: ...lowing can reduce deflect or block radio frequency signals between the transmitter and receiver A Steel reinforced walls B Large metallic objects e g kitchen appliances filling cabinets mirrors etc C...

Page 11: ...transmitter Turn the outer dial clockwise to set the clock hands to the correct time Ensure the time corresponds with the correct time on the 24hr dial 3 00pm 15 00 not 3 00 Note Do not rotate anti cl...

Page 12: ...shing the tappets to the outside Select the OFF times by pushing the tappets to the inside Above shows the clock set as follows ON 3 00pm to 10 00pm 15 00 22 00 OFF 10 00pm to 5 00am 22 00 5 00 ON 5 0...

Page 13: ...Rotate the Minimum dial to a lower temperature down to 5o C to ensure that when the heating is off a minimum room temperature is maintained The clock has a manual heating ON OFF switch which operates...

Page 14: ...14 Notes...

Page 15: ...15 Notes...

Page 16: ...ld you require any assistance during the installation call our Technical Service Helpline on 08707 282 885 option 1 Ferroli Limited Lichfield Road Branston Industrial Estate Burton Upon Trent Stafford...

Reviews: