background image

L E D   S I G N A L S

LED

ENTRY

FLASHING

FIXED ACCESS

1

Led control signal entry

 1

CONTROL OK

ALARM

2

Led control signal entry 

 2.

CONTROL  OK

ALARM

3

Led control signal entry 

 3.

CONTROL  OK

ALARM

4

Led control signal entry 

 4.

CONTROL  OK

ALARM

EXEMPLE OF INSTALLATION

EXTRA NOTES

T h e   p e r i o d i c a l   p h o t o c e l l   t e s t   i s   m a d e   e a c h   1 0   s e c .   a b o u t .   F o l l o w i n g   t h e   r u l e s ,   i n   o r d e r   t o   m a k e   t h e   t e s t   b e   s a f e t y   e f f i c a c e ,     t h e   c y c l e  

m a c h i n e   o f   a u t o m a t i o n   (   O P E N I N G   –   P A U S E   –   C L O S I N G )  

m u s t   n o t   b e   l o w e r   t h a n   1 0   s e c o n d s .

T h e   p e r i o d i c a l   t e s t   h a s   a   t o l e r a n c e   o f   m a x   3 0 0   m s .   I f   t h e   t e s t e d   p h o t o c e l l   d o e s n ' t   a n s w e r   w i t h i n   t h i s   t i m e   t h e   d e c o d e r   p r o d u c e s   a 

m i s t a k e ,   m a k i n g   g o   o f f     t h e   r e l a y .

E a c h   s i t u a t i o n   o f   m i s t a k e   o r   a l a r m   c a u s e s   t h e   a c t i v a t i o n   o f   t h e   r e l a y .

T h e   p a r t   o f   c o n n e c t i o n   b e t w e e n   t h e   c o n t r o l l e r   S A 0 4 P L U S   a n d   t h e   d e c o d e r   o f   t h e   m a c h i n e   i s   n o t   c o n t r o l l e d .   I n   o r d e r   t o   c o n t r o l   t h i s 

l a s t   p a r t   o f     t h e   c o n n e c t i o n ,   t h e   c e n t r a l   o f     c o n t r o l   m u s t   b e   p r o v i d e d   o f   p h o t o c e l l   t e s t .   I n   c a s e   o f   t h e   c e n t r a l   o f   c o n t r o l   i s n ' t   p r o v i d e d 

o f   T E S T ,   y o u   h a v e   t o   w i r e   t h e   d e c o d e r     S A 0 4 P L U S   w i t h   a     l i n e   o f   c a b l e   a s   s h o r t e s t   a s   p o s s i b l e ,   s o   t h a t ,   i n   p h a s e   o f   v a l u a t i o n   o f   r i s k s ,  

i s   p o s s i b l e   t o   d e t e r m i n a t e   a   l o w   f a c t o r   o f   r i s k   i n   t h e   l i n e   o f   c o n n e c t i o n   d e t a i l e d   b e f o r e ,   w i t h   a   r e m o t e   s u p p o s i t i o n   o f   f a u l t   o f   t h e   c a b l e . 

I f   t h e   c e n t r a l   i s   p r o v i d e d   o f   t e s t ,   m o r e   t h a n   t h e   l a s t   l i n e   o f   t h e   c o n n e c t i o n ,   T H E   C O N T R O L   O F   T H E   T E S T   G I V E N   B Y   T H E   C E N T R A L  

O F   C O N T R O L   ,   w i l l   b e   a l s o   u s e d   t o   t e s t e d   t h e   d e v i c e s   s u c h   a s   t h e   p h o t o c e l l .   T h e   p e r i o d i c a l   t e s t   i s   i n d i p e n d e n t   f r o m   t h i s     a n d   i t   w i l l  

r e m a i n   a c t i v e   e a c h   1 0   s e c o n d s ,   a s s u r i n g   m o r e   c o n t r o l     (   i f   t h e     j u m p e r   J 3   i s   o n   ) .

T h e   e n t r a n c e s   t h a t   a r e n ' t   u s e d   h a v e   t o   b e   e n d e d ,   i n s e r t i n g   a   r e s i s t a n c e   o f       8 , 2   K   d i r e c t l y   o n   t h e   c l a m p .

I t   d o e s n ' t   e x i s t   a   m e m o r y   o f   a l a r m   a n d   t h e   L E D   o f   s i g n a l a t i o n   t h a t   c o r r e s p o n d   e v e n t u a l l y   i n   a l a r m ,   i t   w i l l   i n d i c a t e d   t h i s   s t a t e   o n l y   f o r 

t h e   t i m e   o f   t h e   w r o n g   r e a d i n g   o f   t h e   v a l u e .  

  A   h e a t i n g   i n   t h e   z o n e   a r o u n d   t h e     j u m p e r   J 1 ,   i f   t h e   e l e c t r o n i c   i s   s u p p l i e d   w i t h     2 4 V   a c / d c   i s   a b s o l u t e l y   n o r m a l .

M A K E   S U R E   T H A T   T H E   S E T   U P   O F   T H E     d i p   s w i t c h   I S   S U I T A B L E   W I T H   T H E   T Y P E   O F   S A F E T Y S   C O N N E C T E D   T O   T H E   E N T R A N C E S .

INSTRUCTIONS

READ CAREFULLY THE MANUAL BEFORE THE INSTALLATION

The  Ferport s.a.s  do not answer of eventual damages to things and persons dued to a wrong wiring or a wrong use of the product. 

The installation has to be made by specialised staff , following the safety rules.

The Ferport s.a.s  , not knowing the system where the card is installed , doesn't guarantee the right safety of  the structure. 

If the central of control has to be connected where there isn't any safety test, the last line of connection is not protected.  See the risks

The card  SA04PLUS has to be always coupled to a card with logic of working. IT CAN'T  PILOT MOTORS , LAMPS , ECC....

The circuit of alimentation is not protected, so make sure that the central of control or the  card , the trasformer or the feeder that gives tension to the card  SA04PLUS, has  a 

right protection. 

Summary of Contents for SA04PLUS

Page 1: ...a tensioni da 10V a 30V ac dc In genere le centrali di comando forniscono la tensione di alimentazione tipica delle fotocellule Dimensioni elettronica 53 5X71X17 mm circa CONNESSIONI E SEGNALAZIONI M O R S E T T I E R E Morsettiera M1 Morsettiera M2 Morsettiera M3 Morsettiera M4 1 Ingresso 1 5 Ingresso 3 9 Uscita Alim TX NOTOUCH 13 Contatto NC rele sicurezza 2 Ingresso 1 6 Ingresso 3 10 Uscita Ali...

Page 2: ...jumper J3 è inserito Gli ingressi non utilizzati devono essere term inati inserendo una resistenza da 8 2 K direttamente sul m orsetto Non esiste m em oria di allarm e e il LED di segnalazione corrispondente all ingresso eventualm ente in allarme segnalerà questo stato esclusivamente per il tem po per cui perdurerà la lettura errata del valore resistivo Un riscaldam ento nella zona intorno al jump...

Page 3: ...ept tension from 10V to 30V ac dc Usually the central gives voltage of supply typical of the photocell Electronical dimensions 53 5X71X17 mm CONNECTIONS AND SIGNALS T E R M I N A L S Terminal M1 Terminal M2 Terminal M3 Terminal M4 1 Entry 1 5 Entry 3 9 Exit Alim TX NOTOUCH 13 Contact NC safety relay 2 Entry 1 6 Entry3 10 Exit Alim TX NOTOUCH 14 Common safety relay 3 Entry 2 7 Entry 4 11 Entry cent...

Page 4: ...VEN BY THE CENTRAL OF CONTROL will be also used to tested the devices such as the photocell The periodical test is indipendent f rom this and it will rem ain active each 10 seconds assuring m ore control if the jum per J3 is on The entrances that aren t used have to be ended inserting a resistance of 8 2 K directly on the clam p It doesn t exist a m em ory of alarm and the LED of signalation that ...

Page 5: ...on de10V à 30V ac dc habituellement les centrales de commande fournissent la tension d alimentation typique des photocellules Dimensions électroniques 53 5X71X17 mm environ CONNEXIONS ET SIGNALISATIONS B O R N E S BORNE M1 BORNE M2 BORNE M3 BORNE M4 1 Entrée 1 5 Entrée 3 9 Sortie Alim TX NOTOUCH 13 Contact NF relais sécurité 2 Entrée 1 6 Entrée 3 10 Sortie Alim TX NOTOUCH 14 Commun relais sécurité...

Page 6: ...supplémentaire si le jumper J3 è inséré Il faut insérer directement dans la borne une résistance de 8 2 K sur les entrées pas utilisées La mémoire d alarme n existe pas et la LED de signalisation correspondante au entrée éventuellement en alarme signalisera ce état seulement pendant les temps dans le quelle persistera la lecture incorrecte du valeur de la résistance Si l alimentation de la platine...