18
NEO MEET INSTALLER MANUAL
NOTE:
The RTSP route generally has the following format:
rtsp://user:password@camera_IP_address
although it depends on the configuration, brand and model of the camera itself. Please
refer to the corresponding data sheet or technical information.
Nº CÁMARAS:
Select the number
of cameras to be designated,
between 0 and 8. The form will be
adapted to the number of selected
cameras.
For each camera selected, indicate:
o CAMARA X:
Name that will
appear on the monitors during
the display of the camera, for
better identification
o URL:
RTSP path of the
selected camera.
5.5. SIP
Use this setting to configure the SIP monitor as a SIP protocol-based terminal in cases
where the monitor is to be configured as an extension on a SIP server.
• SIP SERVER:
Enter the name
or IP of the SIP server where the
monitor will register.
• DOMAIN:
Enter the domain of
the SIP server
• OUTBOUND, STUN IP:
Used for
the configuration of installations
where SIP server is on Internet.
Check with your network
administrator.
• STUN PORT:
Used for the
configuration of Internet SIP
server-based installations. It is
usually port 5060. Check with
your network administrator.
The available options are:
• ENABLE:
Check this box if the SIP monitor is to be used as a SIP-based terminal.
SEARCH SIP STATUS:
This button appears when enable SIP function, show:
SIP REGISTERED
if the registers is successful or
SIP REGISTER FAILED
if the registers is unsuccessful.
• USER:
Enter the SIP user name or extension to register on SIP server.
• SIP PASS:
Enter the SIP server extension password.
Summary of Contents for NEO MEET