Pag 56
Configuring the Direct Panel
The street panel´s parameters can be programmed on the keypad.
For this you must enter in configuration mode via a programming access code after
pressing ‘A’.
Programming Access code:
A + 4444
(default code).
If the code is correct, a confirmation tone sounds (beep-beep).
The parameters that can be configured are:
Position
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Adjustments
Parameter
Comments
Activation time
lock-Releases
Exit button
activation time
Panel type
Block number
Sub-Block num.
Panel number
Door Sensor Time
Opening code
Programming
Code
MASTER panel
Mode
Guard Unit
Monitoring volume
RESETTING
Parameters
Camera focus
01-99’’
[03]
00-99’’
[06]
0:
Sub-Block
[1]:
Block
2:
E. General
00-99
[00]
00-99
[00]
0-9
[0]
000-250
[000]
not active
0000-9999
[AAAA]
not active
0000-9999
[4444]
[0]: No
1
: Yes
[0]: No Reset
1
: Reset
0-9
[5]
[0]: No Reset
1
: Reset
0-9
[9]
Open-door relay activation from the phone or
access´ control.
Activating lock-release relay from the exit button
(connected to the ‘Bs’ and ‘-’ terminals).
Configuration of the panel type.
Block number the panel belongs to.
Sub-Block number the panel belongs to.
Panel number.
Maximum time the door can be left open after
the lock-release.
Opening code from the keypad. The opening
code is entered as follows:
A + XXXX
(4 digits).
Programming Access code.
Activating the panel as MASTER to program
telephones.
Reset to night mode by writing «1» in this
position.
Adjust street panel monitoring volume
Reset to the default values by writing «1» in this
position.
The selection of different values 0-9, represent
each of the video screens to capture.
For more
details on screen capture, see Camera Focus (next
page).
Possible Values
[
default
]
Summary of Contents for DUOX Video Direct Outdoor Panel
Page 4: ...Pag 4...
Page 35: ...Pag 35...
Page 44: ...Pag 44...
Page 53: ...Pag 53 Section II Programming Manual...
Page 61: ...Pag 61 Section II Manuel de Programmation...
Page 69: ...Pag 69 Teil II Programmieranleitung...
Page 77: ...Pag 77 Sec o II Manual de Programa o...
Page 85: ...Pag 85...
Page 86: ...Pag 86...
Page 87: ...Pag 87...