4
DUOX WIFI VEO XS VIDEO KIT
TECHNICAL FEATURES
PANEL VALUES
Lock-release activation time
01...99 sec. (Default: 03)
Exit button activation time
00...99 sec. (Default: 06) / (deactivated: 00)
Panel type
sub-block/block/general entrance. (Default: block)
Panel number
0..9 (by default: 00)
MASTER panel: not active.
PANEL TECHNICAL CHARACTERISTICS
Power Supply
18 Vdc
Standby Consumption
3,0 W
Audio active consumption
5,0 / 8,6 (max) W
Audio Power in Residence - Entry Panel Direction
1 W
Audio Power in Entry Panel - Residence Direction
0.15 W
Operating temperature
[-25º , +55ºC] / [-13º, 131ºF]
Volume can be Regulated in Both Directions.
WIRING DIAGRAMS
SECTIONS-DISTANCES TABLE
Distance section table - VIDEO KIT INSTALLATION WITH FILTER (1 AND 2 LINES)
SECTION
CABLE
TERMINALS
per home
without additional
power source
Maximum distance (A)
Source/Filter up to Panel
(Panel-Lock release) (i)
Maximum distance (A)
Source/Filter up to Panel
(WITHOUT lock release)
Maximum distance (B)
Source/Filter up to
Panel
Furthest terminal
- (i) For the 12Vdc lock-release and max. consumption 250mA, powered by the amplifier.
MONITOR TECHNICAL CHARACTERISTICS
(OSD TFT 4.3” Screen)
Power supply
18 Vdc
Standby consumption (paired and connected)
1,3 W
Maximum consumption
6,9 W
Operating temperature
[-5º , +40ºC] / [23º, 104ºF]
4. CAMERA FOCUS / LOCK RELEASE ACTIVATION TIME*
To adjust the camera image or adjsut the lock-release activation time.
* See Voice assisted configuration in button panels cod. 970048. Instructions included with this
equipment.
3. ENCODING PANELS*
Whenever there is more than one panel, you must program the number of panels.
40m
Summary of Contents for DUOX CITYLINE VEO XS
Page 43: ...KIT V DEO VEO XS WIFI DUOX 11...