TIME ZONE: 

Setting the time zone of panel. Select local time zone and save. 

 

DAYLIGHT SAVING TIME: 

Shall be enabled for DST periods and disabled for wintertime. 

 
NOTES:  
If  the  installation  has  FERMAX  MANAGEMENT  SOFTWARE,  the  date  and  time  of  panel  will 
synchronize automatically with the management software. If the panel has access to internet, the 
date and time of panel will also synchronize with internet time server. 

If the installation has no FERMAX MANAGEMENT SOFTWARE the installer can set date, time and 
time zone manually. Do not use the GMT (TIME ZONE) adjustment in this case. GMT is usable only 
when the time is automatically taken from internet or FERMAX MANAGEMENT SOFTWARE.  

Date  and  time  cannot  be  saved  after  power  loss  unless  there  were  internet  or  management 
software in the installation. However, the time zone, date format and daylight-saving time can be 
saved anyway. 

Pay attention to the SAVE button related to panel settings or date/time settings since are different 
and independent. 

2.3

 

NETWORK CONFIGURATION 

 

Allows the configuration of the different parameters of the LAN network 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IP: 

IP address to be assigned to this panel

 

MASK: 

Subnet mask corresponding to the LAN

  

 

GATEWAY: 

LAN gateway

 

 

DNS: 

DNS server address. In case of doubt, we recommend using the default value 8.8.8.8. 

 

SOFTWARE IP: 

IP address of the PC where the MEET Management Software is installed (if any). 

Summary of Contents for 9531

Page 1: ...1 INSTALLER MANUAL MILO PANELS INSTALLER MANUAL...

Page 2: ...LECTR NICA applies a continuous improvement policy therefore it reserves the right to modify the contents of this document as well as the product features hereof at any time and without prior notice A...

Page 3: ...NCODE 20 2 12 RESTORE 21 2 13 LOG OUT 22 3 OPERATION 23 4 INSTALLATION 26 4 1 Flush box installation 26 4 2 Installation Guide Diagram 26 4 3 Connectors 27 4 4 Basic diagrams 28 4 5 Installation of th...

Page 4: ...rance by passing their authorized Mifare card The door will open and release the lock The Mifare identifier data must be added through FERMAX MEET MANAGEMENT software Maximum 100 000 Mifare cards By m...

Page 5: ...st be connected to the same LAN as the panel and configured with an IP address in the same range The MILO panel default IP address is 10 1 0 1 Type the IP address of the panel in the address bar of th...

Page 6: ...rovides some technical information regarding the equipment as a reference FERMAX MEET PANEL Device type FIRMWARE Version of the installed firmware DEVICE Type and panel number MAC Panel MAC number IP...

Page 7: ...r of the panel There are some other parameters related depending on TYPE selection GENERAL ENTRANCE PANEL Panel installed in one of the main entrances to a condominium DEVICE NUMBER Number assigned to...

Page 8: ...UME Select the desired value between 1 and 5 Default option is 4 The conversation volume is common for uplink and downlink DOOR OPEN VOICE Enables or disables the speech when door lock is released If...

Page 9: ...usable only when the time is automatically taken from internet or FERMAX MANAGEMENT SOFTWARE Date and time cannot be saved after power loss unless there were internet or management software in the ins...

Page 10: ...ssue is resolved 2 4 ACCESS This section allows some programming related to the access control functionality of the panel DOOR RELAY TIME Time for lock release relay remains active 1 9 s optional OPEN...

Page 11: ...od is used register the resident proximity id numbers on the cards DISARM BY CARD When an already programmed user card is presented to the reader and it has been previously assigned to a monitor the a...

Page 12: ...ion SIMILARITY High medium and low options Default is low NOTES MEET panel face recognition function is based on a bidimensional face identification with the ability of differentiating among photos or...

Page 13: ...de different view angles from the door or related areas NUMBER OF CAMS Select up to 4 different cameras o CAMERA 1 2 3 and 4 IP camera name o URL rtsp user password Ip_adress_of_camera user password f...

Page 14: ...rt function to smartphone trough the FERMAX MEET ME server is used ENABLE SIP Select this box to enable SIP functions SIP SERVER Use the FERMAX MEET server sip sip fermax com DOMAIN Indicate the serve...

Page 15: ...he sip SERVER address Format sip IP_SERVER DOMAIN domain of the SIP server or IP address OUTBOUND Not necessary Leave it in blank STUN IP domain of the SIP server STUN PORT Used for the configuration...

Page 16: ...a PSTN line The panel call can be diverted to user s mobile phone or land line telephone through a voice gateway ENABLE SIP TRUNK Enable or disable SIP trunk function URL URL of the device Format sip...

Page 17: ...devices as well using SIP protocol instead of FERMAX MEET protocol A csv file containing the associated number and the information of the diverted device or devices must be updated to the panel The op...

Page 18: ...r to call c In the case of a call to a third party SIP device through a SIP server APARTMENT sip user IP_SIP_SERVER where user is the identification user that the device to call has been programmed in...

Page 19: ...ce 1234 of the SIP server with IP 192 168 1 170 and to the monitor IP 192 168 1 195 in the installation Apartment 183 generates a call to the SIP device 1234 of the SIP server with IP 192 168 1 170 an...

Page 20: ...rowser Enter the current code the new pin and confirm it The new password can have alphanumeric characters and has no limit on its length Finally select SAVE NOTE Make a note of the new PIN at your co...

Page 21: ...1 APARTMENT 101 for 1W panel operation LANGUAGE ENGLISH VIDEO RESOLUTION 640 x 480 NETWORK IP 10 1 0 1 MASK 255 0 0 0 GATEWAY 10 254 0 1 DNS 8 8 8 8 SOFTWARE IP 10 0 0 200 INSTALLER PASSWORD 1234567 A...

Page 22: ...22 2 13 LOG OUT Use this functionality if you want to end your working session with this panel The panel will request access credentials again in the case of new access via web server...

Page 23: ...creen allows basic information for the users alternating information of how call apartments and how call concierge This screen is usually in off state to save energy but it turns on automatically at t...

Page 24: ...ing an ACCES PIN code Dial A0 to enter in PIN CODE mode The panel admits up to 8 different ACCESS PIN CODE that must be programmed by the installer Length of each ACCESS PIN CODE could be between 4 to...

Page 25: ...ertain day The panel shall have installed a GUEST CODE MODULE Ref 1494 and a third party Access Control System is required Dial A7 to enter in GUEST CODE mode ON SCREEN INFORMATION It is possible to g...

Page 26: ...anel is stuck in then move the panel to the flush box 4 Move the slider of the panel and fix the two screws When installing pay attention to the reservation of the 2 cm space around the door to move t...

Page 27: ...e alarm block doors unlock contacts DS Connection for door opened sensor RS485 Output for Ref 1491 Ref 9545 MEET LIFT Control Gateway Ref 1494 Guest code or Ref 1490 External Relay Ref 1490 works in t...

Page 28: ...concierge and FERMAX MANAGENEMN SYSTEM if exists 4 4 Basic diagrams 4 5 Installation of the 4 RELAY MODULE REF 1491 This module is necessary if you want to use the facility of activating from the moni...

Page 29: ...29 4 6 Diagram installation of the GUEST CODE Module Ref 1494 4 7 Diagram installation of the lift control system This installation has to be performed in the PANEL n 1 of the corresponding block only...

Page 30: ...t 400 1 Brightness 200 cd m2 Audio Features G 711 codec Audio OLR 15dB Camera 1 3 CMOS Colour 72 H 54 V 1 2 Mega Pixels Minimum Illumination 0 5 LUX Automatic white led activation AWB Working Environm...

Page 31: ...ware update is performed via the MEET System Upgraded Tool V 1 2 exe The procedure for updating the firmware with the corresponding update file is as follows It is possible to update several panels at...

Page 32: ...and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that inte...

Reviews: