Page 2: ...ELECTRÓNICA applies a continuous improvement policy therefore it reserves the right to modify the contents of this document as well as the product features hereof at any time and without prior notice Any modification will be reflected in subsequent editions of this document This product is protected with the following patents and utility models PATENTS US 9215410 US 9762852 BE1023440 AU2014203706 ...

Page 3: ...s 9 4 2 Basic configuration of the MONITOR 10 4 3 Configuring the alarm settings 13 4 4 Enable disable FUNCTIONS 14 4 5 Enable third party APPs 15 4 6 Change INSTALLER PIN 16 5 WEB BROWSER PROGRAMMING 17 5 1 DEVICE 18 5 2 GENERAL 18 5 3 NETWORK CONFIGURATION 19 5 4 IP CAMERA 20 5 5 SIP 21 5 6 ADVANCED 21 5 7 ACTUATORS 23 5 8 CHECK 24 5 9 PIN CODE 24 5 10 RESTORE 25 5 11 LOG OUT 26 6 ANNEXES 27 6 1...

Page 4: ... REF 952201 MONITOR MIO WHITE 7 REF 952203 MONITOR MIO BLACK 7 REF 952701 MONITOR MIO WHITE 10 REF 952703 MONITOR MIO BLACK 10 REF 14701 MONITOR WIT 7 POE WHITE REF 14703 MONITOR WIT 7 POE BLACK REF 14811 MONITOR WIT 10 POE WHITE DOMOTICO REF 14813 MONITOR WIT 10 POE BLACK DOMOTICO Network failures Alarm Mode Date and time Missed calls Received messages Do not disturb Settings ...

Page 5: ... cable power supply and accessories if any arrive Use the screws and plugs supplied with the monitor to attach the stand 2 2 Attaching the monitor to the stand Once the stand is in place proceed to hang the monitor To do this snap the 4 connector anchors into the corresponding slots on the back of the monitor and push down on the monitor to attach it Don t forget to pre connect the ethernet networ...

Page 6: ...s LAN installation PoE for WIT monitors No PoE for MIO monitors LAN 2 Ethernet connector to the home s local LAN installation Only WIT 10 monitor 12V 12 Vcc power input for non PoE installations Siren Sensors o S 12 Vdc auxiliary output synchronised with the activation of any sensor The maximum current is 100 mA o GND o Z1 Z7 sensor inputs Z8 is reserved for tamper 12V 485 485 Power output and RS ...

Page 7: ...which the monitor would detect sabotage in the sensor loop shorting or cutting the sensor loop To enable this option connect a 2 2 Ohm resistor according to the diagram and enable the 3C function in the monitor See section 4 3 Configuring the alarm settings A bag with 8 resistors is included with the monitor Triggering any sensor activates the S output for 2 minutes except when configured as a doo...

Page 8: ...trolled use the relay outputs 0 to 7 corresponding to the activations R1 to R8 of the monitor control screen Relay outputs 8 and 9 are not used The module Ref 1616 is powered directly from the monitor No additional power is required NOTES The module Ref 1616 only activates the corresponding relay during the time indicated in the programming between 1 and 60 seconds After this time the relay automa...

Page 9: ...onitor idle current 200 mA working current 500 mA 10 monitor idle current 210 mA working current 600 mA Resolution 1024 600 pixels Touch screen Capacitive technology Maximum conversation time 120 secs Maximum time to answer the call 35 secs Maximum auto on time 30 secs Maximum recording time 30 secs Maximum number of IP cameras 8 Block 001 999 Apartment 0001 9899 Working temperature 10 55 Relative...

Page 10: ...ing to the requirements of the LAN It is therefore necessary to carry out prior planning of the installation with the IP address to be assigned to each and every one of the components of the installation monitors panels and guard units 4 1 Installer access From the idle screen access the installer section by touching the icon Touch the icon to access the programming parameters through the interfac...

Page 11: ...onfiguration IP addressing LAN configuration block housing etc Configuring the built in alarm settings Enable disable user functions Installation of third party APPs and other MEET APPs such as Lift Control or actuators Change the INSTALLER PIN code 4 2 Basic configuration of the MONITOR Touch the icon to access the basic configuration parameters ...

Page 12: ...e the MEET Management Software is installed if any SW PIN Management Program ACCESS PIN code The default option is 123456 NETWORK SETTINGS IP IP address to be assigned to this monitor MASK Subnet mask corresponding to the LAN GATEWAY LAN gateway DNS DNS server address of the LAN In case of doubt we recommend using the default value 8 8 8 8 After all data has been entered correctly a confirmation m...

Page 13: ... your network administrator USER Enter the SIP user number SIP PASS Enter the SIP server user PASS NOTES Before programming the monitors it is necessary to plan the installation with the following criteria Assign a unique IP to each element of the installation including the PC where the MEET Management Software is installed if any All IP addresses must be in the same range The LAN to be used must ...

Page 14: ... triggered silently i e by giving a warning to the control station but without sounding on the monitor SENSOR Choose the type of sensor used in this area between SMOKE GAS MOTION DOOR WINDOW PANIC TAMPER and SOS This is the information that will appear on the monitor screen after the corresponding alarm is triggered ARRIVAL Choose between 3C NA NC or BELL 3C If you have used the anti tamper monito...

Page 15: ...warned by a message on the screen It will not be possible to change the mode until the incident has been corrected This makes it possible for example to avoid false alarms or security failures if a door or window is left open at the time that NIGHT or OUT mode is selected 4 4 Enable disable FUNCTIONS Touch the icon to select which functions are to be available to the user and which functions are t...

Page 16: ...plications specific to the MEET monitor Lift control message reception SOS alarm scene control or actuator control The icon for a disabled function will not appear on the screen Select the required application along with 2 other applications It is always necessary to select 3 applications at a time between installed applications and the MEET monitor s own applications Tap on the message SELECT APP...

Page 17: ...urrent PIN and enter the new PIN Confirmation of the new PIN is requested for security purposes NOTES If the INSTALLER PIN is changed via WEB browser it can be longer and contain alphanumeric characters See section 5 9 PIN CODE But in that case it cannot be used to access the configuration from the monitor itself Make a note of the new PIN at your convenience If you lose or forget your PIN you sho...

Page 18: ...dress is 10 1 1 1 However this address can be changed or consulted via the local programming of the monitor See section 4 2 Basic configuration of the MONITOR Type the IP address of the monitor in the address bar of the browser An identification form will appear The default identification data are User name admin Password 6666 A form will appear with the different programming sections NOTES Prefer...

Page 19: ... apartment where the monitor is installed 3 digits 001 009 APART Number of the apartment where the monitor is installed 4 digits 0001 9899 MONITOR Number from 0 to 9 assigned to each of the monitors installed in the same apartment if there are several If there is only one leave the default value 0 SYNC CODE Synchronisation code with the rest of the monitors installed in the same home It has to be ...

Page 20: ...gement Software is installed if any SOFTWARE PIN PIN ACCESS code for the Management Program control The default setting is 123456 Indicate the corresponding parameters and click on SAVE to confirm NOTE The MEET system uses static IP addressing This ensures that each device has a unique IP address in the same installation If a device has an IP address already assigned to another device on the netwo...

Page 21: ...onfiguration of the relay is done when programming of ACCESS PANEL 1 of the corresponding block o URL RTSP path of the selected camera DOORBELL CAMERA If a doorbell has been installed on the monitor see installation section this drop down will indicate which camera 1 2 or none is associated with it it will light up when someone rings the doorbell NOTE The RTSP route generally has the following for...

Page 22: ...on fibre optic links Check with your network administrator STUN PORT Used for the configuration of SIP server based installations It is usually port 5060 Check with your network administrator USER Enter the SIP user number SIP PASS Enter the SIP server access PASS CONVERSATION Indicate the maximum conversation time in communications with SIP protocol NOTE The MEET monitor must be registered with t...

Page 23: ...s of that device o sip user domino_server_sip in case of diversions to a third party SIP device AUTO ANSWER Check this box if you want the monitor to automatically pick up when a call is received if it is not answered manually within 10 seconds UN GPON Used in large installations based on SIP protocol GPON and in combination with the configuration of said installations DTMF UNLOCK Generally panels...

Page 24: ... are connected to a 4 Relay Meet Module Ref 1491 connected to panel nº 1 of the block where the monitor is installed MILO DIGITAL or KIN panels only 5 7 ACTUATORS Use this section to enable and name the actuators that this monitor can control Indicate ACTIVATE the relays to be enabled and write the name or description that should appear on the monitor when you want to control any of them Select th...

Page 25: ...ge the INSTALLER PIN code to access both the installation configuration parameters through the monitor s own screen and the configuration through a web browser Enter the current code the new pin and confirm it The new password can have alphanumeric characters and has no limitation on its length However if the password does not contain just 4 numerical digits it cannot be used from the monitor inte...

Page 26: ... BLOCK 1 APARTMENT 101 NUMBER 1 NETWORK IP 10 1 1 1 GATEWAY 10 254 0 1 GATEWAY 255 0 0 0 INSTALLER PASSWORD 6666 Any other parameters sip actuators IP cameras etc that have been configured will also be lost REBOOT DEVICE The monitor will automatically turn off and start up but retain all the programming parameters it had previously When resetting the device will lose connection with the PC Refresh...

Page 27: ...26 5 11 LOG OUT Use this functionality if you want to end your working session with this monitor The monitor will request access credentials again in the case of new access via web server ...

Page 28: ... uninstall the APP through a PC connected to the same LAN as the monitor and using the MEET System Upgrading Tool exe program is as follows 1 Sta rt the MEET System Upgrading ToolV01 00 exe 2 Browse the PC to find the location of the img file corresponding to the installation of the APP 3 Indicate the IP of the monitor 4 Select UPGRADE The application will be installed in a few seconds and will be...

Page 29: ...the corresponding update file The firmware update is performed via the MEET System Upgrading Tool V01 00 exe The procedure for updating the firmware with the corresponding update file is as follows 1 Start the MEET System Upgrading Tool v1 00 exe 2 Browse the PC to find the location of the corresponding update file 3 Indicate the IP of the monitor 4 Select Upgrade The new firmware will be installe...

Page 30: ...nterference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the recei...