6.1.4 RESETTING ERRORS, TURNING THE HEATER ON AND OFF
If you long press the
(P1) button, the heater´s state will change from the one it was in before the button was
pressed.
The following circumstances could arise:
STATE BEFORE LONG PRESS
STATE AFTER LONG PRESS
STOP (no alarm) (The display shows the time and the
room temperature)
ON (The display shows Chec, ON1, ON2,...)
STOP (with alarm) (The display shows Er02 [example]
and ALT intermittently)
STOP (no alarm) (The display shows the time and the
room temperature)
ON, NORMAL, MODULATION OR STANDBY
OFF
OFF
`rec´(Turn on recovery)
“rec” (Turn on recovery)
OFF
6.1.5 LOADING THE PELLET SCREW
This function allows you to fill the screw for the first time that the heater is going to be started up and also when, for
whatever reason, the fuel tank has been completely emptied.
This is done by pressing the
(P3) button, with the loading screw being activated continuously. Whilst the lower
display shows `
LoAd
´, the upper display will show for how long it has been operating. Stop loading when the pellets
fall uninterrptedly into the brazier, which can be achieved by pressing any button. For safety reasons, loading is
automatically interrupted after 300 seconds.
AFTER CARRYING OUT THIS OPERATION, BEFORE PROCEEDING
TO TURN THE HEATER ON, IT IS NECESSARY TO EMPTY THE
BURNER AND REPLACE IT CORRECTLY. IF IT IS NOT CORRECTLY
REPLACED, IT COULD CAUSE DIFFICULTY WHEN TURNING THE
UNIT ON
Summary of Contents for AROA 10
Page 1: ...Quality of Life MANUAL FOR THE USER AND INSTALLATION AIR RANGE COD 0153 R2 INGL S...
Page 2: ...2...
Page 11: ...11 MODEL FLORA 7 8 kW MODEL NEREA 8 10 kW...
Page 12: ...12 MODEL NATALIA 10 kW MODEL AROA 8 10 kW...
Page 13: ...13 MODEL NEREA 12 15 kW MODEL LUNA 8 10 kW...
Page 14: ...14 MODEL ESTELA 12 15 kW MODEL G NESIS 6 8 kW...
Page 46: ...46...