1.6.2 Maintenance to be made daily or at 10 hours intervals
1.6.2.1 Do a check for the engine oil level
Procedure
1.
Stop the engine.
2.
Wait for approximately 15 minutes.
3.
Do a check for the oil level.
The oil level must be between the MAX and
MIN lines on the oil dipstick.
4.
Add oil, if necessary.
a) Clean the oil filler plug and the
surroundings.
b) Top up to the MAX line.
NOTE:
Overfill causes excessive oil splash in
the crankcase, which results in increased oil
consumption and malfunction in crankcase
ventilation system (CCV). Major engine
damage can occur.
GUID-1595BCA1-ABA4-4E4C-87A1-AE5516435C98-high.eps [High]
Fig. 21
1.6.2.2 Check coolant level
The coolant level should be slightly above the radiator core.
The coolant level should be between the MAX and MIN lines if the system is provided with an expansion
tank.
Check the freezing point of the coolant before the cold season.
NOTE:
Use only coolant that is a mixture of 40-60% water and antifreeze. Refer to the engine specification for the
machine, for the specified ratio and the quantities necessary. Do not use water only for the coolant.
NOTE:
The hot engine can be damaged if you pour cold coolant into it!
WARNING: Hot pressurized coolant. It is dangerous to open the cap of the pressurized hot
radiator.
Injury from the release of hot pressurized coolant.
Carefully open the radiator cap slowly.
[V]
GUID-F4FBA864-3D6B-4B7B-B9C4-9553DDF97DF0 [V4]
GUID-86DC7196-65D2-412C-A8BA-FDCB9A8492F3 [V1]