Power supply and connecting cables

•    Cables that are laid in the ground (soil) must be protected by solid insulator pipes or use

    insulated high-voltage cables designed for this purpose. Make sure that the cables will 

    not be damaged by, for example animal hooves or tractor wheels, which can sink into the

    ground. Do not use standard electrical cables.
•   Cables must not be placed in pipes together with other circuit, communication or data cables.

 

Supply and connecting leads and electric line of fence system: 

•  Shall not cross above overhead power or communication lines. Crossings with overhead

   power lines shall be avoided wherever possible. If such a crossing cannot be avoided it shall

   be made underneath the power line and as nearly as possible at right angles to it.
•   If are installed near an overhead power line, the clearances shall not be less than those

    shown. 

•  If are installed near an overhead power line, their height above the ground shall not

   exceed 3 m. This height applies to either side of the orthogonal projection of the outer

   most conductors of the power line on the ground surface, for a distance of:
      •   2 m for power lines operating at a nominal voltage not exceeding 1000 V

      •   15 m for power lines operating at a nominal voltage exceeding 1000 V
•  Being nearby telephone line or telephone cable, must be conducted at a distance of 

minimum of 2 metres. 
Electric animal fences intended for deterring birds household pet containment or 

training animals such as cows need only be supplied from low output energizers to obtain 

satisfactory and safe performance. 
In electrical animal fences intended for deterring birds from roosting on buildings no fence 

wire shall be grounded if the fence wires are not connected to metal parts. If one wire is 

connected with a metal part (ie a gutter) or a metal structure of the building these metal 

parts must be grounded. A warning sign shall be fitted to every point where persons may 

gain ready access to the conductors. 
Where an electric animal fence crosses a public pathway, a non-electrified gate shall be 

incorporated in the electric animal fence at that point or a crossing by means of stiles shall 

be provided. At any such crossing, the adjacent electrified wires shall carry warning signs.
Avoid direct contact with fencing, especially with head, neck or upper part of body. Do not 

creep through the fencing or over it. For passing the fence system, use a gate or another 

point in installation designed for this purpose.

Power line voltage

Clearance

 ≤ 1000 V

 3 metres

 > 1000 ≤ 33000 V

 4 metres

 > 33000 V

 8 metres

Overvoltage protective equipment – lightning diverter

To prevent from damages caused by lightning, we recommend leading a circuit of fence 

system near to building via overvoltage protective equipment – lightning diverter fastened 

to outer masonry of the building by means of non-combustible materials before its 

connecting to energizer. This applied also for combined energizers, if they are used 

together with a network adapter.

Summary of Contents for power energy PE60

Page 1: ...wer energy PE60 230 V STORED ENERGY OUTPUT ENERGY OUTPUT VOLTAGE OUTPUT VOLTAGE 500 SWITCHING ON OFF fencee power energyPE60 EXTREMEPOWER 5 5 J 5 J 12 500 V 10 000 V 800 km 70 km 25 km 10 km 420 730 8...

Page 2: ...rsk 605 563 01 Lan kroun I O 64793826 declares that the below listed products are in accordance with requirements of standards and regulations relevant for given type of devices Products are safe unde...

Page 3: ...to safety regulations in accordance with valid legislation as well as relevant EU CE regulations We also ask you to read these instructions for use before using the device carefully and to keep it fo...

Page 4: ...appliance Damage to all connected devices and appliances may occur in the event of lightning strike The device may only be repaired by the manufacturer s qualified personnel Please dispose all waste i...

Page 5: ...impulse lasts for a matter of milliseconds These fences serve not only to enclose an area but also act as a deterrent e g to protect against wild boars Benefits of electric fence systems Electric fenc...

Page 6: ...tems operation The energizers power energy PE power output is then automatically adjusted to keep the required output vol tage in the widest possible load range This control significantly aids in savi...

Page 7: ...f function 4 ON OFF switch button 5 Earthing black 6 Connection to fence system red 6 PRODUCT DESCRIPTION 1 2 3 4 5 6 Explanations of symbols shown on energizer Earthing connection Connect this connec...

Page 8: ...ADY TO USE Choose a place suitable for installation of energizer Where you can achieve a good earthing Which is distant enough from children and animals Where energizer is well accessible Where perman...

Page 9: ...rew or DIN rail with mounting bracket in vertical position at least 20 cm above ground Never expose energizer to continuous water stream ON THE GROUND IN A PUDDLE ON THE GROUND UPSIDE DOWN NEGATIVE AN...

Page 10: ...al supplementary earthing rods with length of minimum of 1 m and place them at distance of approximately 3 meters from each other Exceptions are fence system powered by battery energizer or working wi...

Page 11: ...required to be smaller Do not use barbed or razor wire or any other types of sharp edged wire to install the electric fence system Non conductive additional fencing in which barbed or razor wire is us...

Page 12: ...deterring birds household pet containment or training animals such as cows need only be supplied from low output energizers to obtain satisfactory and safe performance In electrical animal fences inte...

Page 13: ...f connecting lines of this energizer are damaged they must be replaced by manufacturer or authorized service or another qualified person so that possibility of danger is excluded Service and repairs o...

Page 14: ...Highvoltage cable is recommended Conductor has adverse properties thin diameter high resistance Use high quality conductor with low resistance and larger diameter Ensure high quality correct connectio...

Page 15: ...e It expires in case of interferences by unauthorized persons and in case of using spare parts of foreign origin All deficiencies resulting from material defects or manufacturing defects shall be remo...

Page 16: ...and signature of seller VNT electronics s r o Dvorsk 605 563 01 Lan kroun Czech Republic info fencee eu 420 730 893 828 PRINT fencee cz fenceeczech Electric fencing www fencee eu www fenceefarm com ww...

Reviews: