15
ON THE GROUND - IN A PUDDLE
ON THE GROUND - UPSIDE DOWN
NEGATIVE
ANGLE
NEVER EXPOSE TO
A CONTINUOUS
STREAM OF WATER!
VERTICAL ON THE
WALL IDEALLY
WITH A CANOPY
We recommend
mounting on DIN rail
80 mm (Art.Nr. 8043)
•
Energizers must be installed in a dry place.
•
Never put energizer on ground – in moist or wet environment.
•
Fasten energizer by means of hanging screw or DIN rail with mounting
bracket in vertical position – at least 20 cm above ground.
•
Never expose energizer to continuous water stream.
Earthing
Correct earthing is very important because total function of the fence system is
dependent on it!
Beat earthing rod with corrosion protection into ground completely at place with maximum
and permanent humidity. On dry pieces of land or in case of soils with lower electric
conductivity, use one or several supplementary earthing rods (with length of minimum of
1 m) and place them at distance of approximately 3 metres from each other.
Exceptions are fence system powered by battery energizer or working with low output. Here
minimum length of earthing rod of 50 cm is recommended. Distance of at least 10 metres must
be between earthing rod of fence system and another earthing system, for example earthing
of a house, protective earthing of electric supply system or earthing of violation alarm.
Do not connect the energizer to already existing earthing.