22
9.
EXPLANATION OF LED INDICATING LIGHTS AND BARGRAPH INDICATOR
Indicating statuses are as follows:
LED control:
BURNING / BLINKING
•
blinking
operation on battery only
•
permanent burning
– operation with adapter
COLOR
•
blue
operation at higher output (100 %)
•
purple
operation at lower output (c. 50 %)
•
red
it lights up when battery voltage drops below 12 V.
When battery voltage drops below 11,6 V, warning siren is started (beeping). When battery
voltage drops below 11,4 V, energizer is switched off. Reason is protection of battery from deep
discharge of the battery (battery destruction). If discharged battery and adapter are connected
simultaneously, red LED is burning, until battery is charged at 12 V at least.
BARGRAPH INDICATOR:
To indicate input voltage at fence system,
power DUO RF PDX
models are equipped with
BARGRAPH indicator. It consists of six LEDs
- 2× RED
I
2× YELLOW
I
2× GREEN
– ordered
from left to right. BARGRAPH indicator always goes through LEDs from the first red one up to
indicated position where it stops for a while.
–
–
–
–
LED
BARGRAPH INDICATOR
RED
YELLOW
YELLOW
GREEN
GREEN
YELLOW
YELLOW
GREEN
GREEN
YELLOW
GREEN
GREEN
GREEN
GREEN
GREEN
RED
RED
RED
RED
RED
YELLOW
RED
RED
YELLOW
YELLOW
RED
RED
YELLOW
YELLOW
GREEN
RED
RED
YELLOW
YELLOW
GREEN
GREEN
•
voltage
< 3 kV
- 1× RED
•
voltage
3-5 kV
- 2× RED
•
voltage
5-6 kV
- 1× YELLOW
•
voltage
6-7 kV
- 2× YELLOW
•
voltage
7-8 kV
- 1× GREEN
•
voltage
> 8 kV
- 2× GREEN
RED
RED
YELLOW
YELLOW
GREEN
GREEN