background image

7

5.2 Energizers energy DUO RF EDX with power output higher than 5 J

Standard’s special requirements must be observed for energizers with power output higher 

than 5 J, namely time cut-off limit when the power output is increased and thus ensuring 

safety.

Products must be identified by   

 mark.  

fencee energizers have time cut-off limit of 50 seconds, which means that whilst the fence 

system is under load and its resistance drops below 500 Ohm (overgrown grass, fallen branches, 

etc.), the energizer will supply the maximum of 5 J for 50 s. If the fence system resistance does 

not increase during this time (carrying out corrective measures), the energizer will gradually 

increase the power output (e.g. EDX150 model up to 15 J).

Acoustic and visual warning when the fence system is suddenly under load is another feature. 

If the fence resistance drops abruptly during one pulse from over than 1,000 Ohm to less than 

400 Ohm (fallen branches, tangled animal or human, etc.), alarm is triggered after six pulses, 

acoustic warning and red LED indicator light flashes. At the same time, the pulse period is 

shortened to 3 s. The alarm is switched off after increasing the fence resistance to more than 

600 Ohm or after the time limit of 10 min. Both functions are independent and separate.

Energizers 

energy DUO RF EDX

 may also be remotely controlled from the FENCE GATEWAY 

GW10, which cannot be connected to Wi-Fi, consequently you will not be able to control using 

mobile phone or via web interface, only from the gateway.

Summary of Contents for Energy DUO RF EDX80

Page 1: ... 8 J 10 000V 7000 V fencee energyDUORFEDX100 13 J 10 J 10 000V 7000 V fencee energyDUORFEDX120 15 J 12 J 10 500V 7500 V fencee energyDUORFEDX150 20 J 15 J 10 500V 7500 V 230 km 80 km 17 km 8 km 300 km 90 km 22 km 10 km 320 km 100 km 25 km 13 km 350 km 120 km 28 km 16 km Control and monitor through mobile application PHONE CONTROL Compatible FENCE WiFi GATEWAY GW100 FENCE GATEWAY GW10 FREE APP fenc...

Page 2: ... of conformity is issued pursuant to these materials Issued by accredited Státní zkušebna strojů a s Třanovského 622 11 163 00 Praha 6 This declaration is issued at explicit responsibility of the manufacturer In Lanškroun January 29th 2021 Ing Jan Horák Executive Head of the Company Phone 420 730 893 828 info fencee eu www fencee eu DECLARATION OF CONFORMITY ENERGIZERS FOR ELECTRIC FENCES fencee e...

Page 3: ... 2014 35 EU 2014 30 EU Low Voltage Directive Electric appliances for domestics and similar purposes Safety Part 2 76 Special requirement on energizers for electric fences relate to the fences R TTE EN300 220 a EN 61000 6 3 2007 A1 2011 1 CONTENT 1 Content 3 2 Importantrecommendations 4 3 Package contents 4 4 Function electric fence 5 5 Introduction 6 5 1 Remote control 6 5 2 Enerizers EDX with pow...

Page 4: ...n the electric fence system Read thoroughly the Safety Guidelines paragraph Strictly observe all safety guidelines during installation work Do not connect the device on one fence system to another appliance Damage to all connec ted devices and appliances may occur in the event of lightning strike The device may only be repaired by the manufacturer s qualified personnel Please dispose all waste in ...

Page 5: ...e lasts for a matter of milliseconds These fences serve not only to enclose an area but also act as a deterrent e g to protect against wild boars Benefits of electric fence systems Electric fences are long lasting simple to put up and great value for money compared with normal fences It is easy to assembly and flexible for using Designed for guarding and protecting different animals Compared to ot...

Page 6: ...n adequately high fence system voltage which is for example overgrown with grass high load LED indicator lights and BARGRAPH on the front of the energizer show the power supply sta tus and fence system voltage and also signal any potential faults on the fence 5 1 Remote control Energizers energy energy DUO RF EDX may be remotely controlled using RF technology and Cloud application it is also essen...

Page 7: ...gradually increase the power output e g EDX150 model up to 15 J Acoustic and visual warning when the fence system is suddenly under load is another feature If the fence resistance drops abruptly during one pulse from over than 1 000 Ohm to less than 400 Ohm fallen branches tangled animal or human etc alarm is triggered after six pulses acoustic warning and red LED indicator light flashes At the sa...

Page 8: ...y of earthing Cloud connection Using FENCE WiFi GATEWAY GW100 Power switching Manual switching between the high and low power output option for reducing demand on the battery Up to date information Online up to date information on all devices Control from phone Control and monitor using the fencee Cloud mobile application Alarm signalling Immediate problem alert sent to the phone and e mail Combin...

Page 9: ...onnection monitoring and status indication shown on LED display 5 BARGRAPH shows fence system voltage 6 Push button for selecting particular display 7 Push button used for confirming Changing values 8 ON OFF button 9 Earthing black 10 Connection for measuring the quality of earthing green 11 Connection to fence system with reduced power yellow 12 Connection to fence system red Reduced power fence ...

Page 10: ...nent water stream is avoided To mount energizer on wall use attached screws on which you can hang the energizer easily 1 2 3 3m Energizer min 20 cm above the ground MIN 1m 3m Assembly of energizer by using DIN rail Energizer can be easily and practically mounted by using DIN rail and mounting bracket Set for assembly on DIN rail can be ordered as separate accessories Min 10 metres from next earthi...

Page 11: ...or working with low output Here minimum length of earthing rod of 50 cm is recommended Distance of at least 10 metres must be between earthing rod of fence system and another earthing system for example earthing of a house protective earthing of electric supply system or earthing of violation alarm Do not connect the energizer to already existing earthing Antenna installation Screw the RF antenna ...

Page 12: ...oals calves It is also connected separately to the larger fence system lower wire where vegetation is expected to be dense with technical measures to prevent losses namely voltage leakage to the ground as it is usual in standard connections thus the energizer power output is not reduced The other wires connected to the red output are powered separately at full voltage Green output is intended for ...

Page 13: ...e energizer shows impedance of 500 Ohm or lower i e long or overgrown fence system then there is no need to install anything else and the earthing check works automatically Check the ground voltage on the energizer according to the below table If the fence system impedance is higher than 500 Ohm i e quality fence not subjected to load then it is required to short circuit the fence system to enable...

Page 14: ...itched on Short press No response ENERGIZER IS SWITCHED ON BY PRESSING PUSH BUTTON Long press 2 s Manual switching between the high and low power output approximately 50 User selectable when for example it is used for more sensitive animals or to reduce demand on battery if required The low power output is always limited to the maximum of 5 J Short press Energizer is put into the Standby Mode ENER...

Page 15: ... V at least BARGRAPH INDICATOR To indicate input voltage at fence system energy DUO RF EDX models are equipped with BARGRAPH indicator It consists of six LEDs 2x RED I 2X YELLOW I 2X GREEN ordered from left to right BARGRAPH indicator always goes through LEDs from the first red one up to indicated position where it stops for a while A fast blinking blue indicates the pairing mode of the energizer ...

Page 16: ...ce of the fence but also graphically with an icon of overgrown grass Setting screen On the first and second screens you can select between the displayed parameters using the confirmation button There are three options that repeat in a circle output voltage kV battery voltage V and output energy For entry to setting screen hold for 2 s Setup button You can use the confirm button to access the indiv...

Page 17: ...tput performance Data indicating the ener gizer output needed in the present condition of the fence due to its loading and losses Measuring earthing Error message Icon indicating the connection of a battery and its status Indicates connection to the grid Full battery blue violet led over 12 V Half battery red led 12 11 6 V Empty battery red led siren 11 6 11 4 V The energizer will shut down méně n...

Page 18: ...n can be caused by many diffe rent ones reasons Therefore in such a case it is necessary to send the energizer to our Service Department for a specialist inspection and repair 1000 ohm a short pen with minimum greenery 1000 ohm medium pen with mild growth of vegetation 500 ohm longer pen mild growth of greenery 300 ohm longer pen medium growth of greenery or mild growth after rain 300 ohm a pen wi...

Page 19: ... 0 kV the voltage alarm is off Light Setting the backlight time Here you can set the values of 1 minute 5 minutes and continuous light ON Contrast Setting the display contrast in the range 90 150 The following items are available Back This serves to leave the settings menu Select the BACK item Confirm your choice You can toggle among screens 1 2 Enter the screen Select an item Confirm the selectio...

Page 20: ...ings button to enter the settings screen Settings screen Use the enter button to enter the settings Entering the settings menu Use the settings button to select an item Selection of a required item Use the enter button to select adjustment of an item Adjustment of an item Changing the value Use the enter button to confirm the given value Changed value Use the settings button to change the value ...

Page 21: ... address One fence may be paired on the maximum of 3 gateways By selecting RESET all paired gateways may be deleted from the fence system which also changes the fence MAC address This means that the gateway will not be able to send or re ceive data from the energizer The function is used to remove the energizer from the gateway for example when selling the fence so that the original owner is not a...

Page 22: ... road Warning sign It is of yellow colour with minimum dimensions of 100 x 200 mm It is either standard warning sign or contains the following Inscription on both sides WARNING ELECTRIC FENCE Letters must be at least 25 mm high and indelible One warning sign is included in the package contents Power supply and connecting cables Cables that are rated for voltages higher than 1 kV and are located in...

Page 23: ... parts If one wire is connected with a metal part ie a gutter or a metal structure of the building these metal parts must be grounded A warning sign shall be fitted to every point where persons may gain ready access to the conductors Where an electric animal fence crosses a public pathway a non electrified gate shall be incorporated in the electric animal fence at that point or a crossing by means...

Page 24: ...professionally If connecting lines of this energizer are damaged they must be replaced by manufacturer or authorized service or another qualified person so that possibility of danger is excluded Service and repairs of these energizers must be performed by authorized persons only Each user of electric fence system is responsible for its operation and should perform regular checks of energizer and f...

Page 25: ... red LED will be burning Lead in or short circuit of supply lines of the fence system Do not use conventional cables for supply lines High voltage cable is recommended Conductor has adverse properties thin diameter high resistance Use high quality conductor with low resistance and larger diameter Ensure high quality correct connection of conductors Low quality earthing too short earth rod corrosio...

Page 26: ...ects or manufacturing defects shall be removed in manufacturer s discretion by repairing or free of charge replacement of the energizer In case of delivering spare parts or repairing original guarantee period is not prolonged Guarantee period and address of guarantee provider can be found in attached instructions for use of given type of energizer Accumulators or batteries of any type damages due ...

Page 27: ...Y 8 J 10 J 12 J 15 J OUTPUT VOLTAGE 10000 V 10000 V 10500 V 10500 V OUTPUT VOLTAGE 500 Ω 7000 V 7000 V 7500 V 7500 V LCD DISPLAY ON OFF LED ON OFF LED IMPULS LED LOW BATTERY VOLTAGE LED POWER LOWER 50 LED ERROR CHECK LED IMPULS BARGRAPH TIME DELAY EARTHING 1 M 4 5 5 6 EL FENCE NETTING 22 27 32 38 DATA ENCODING TRANSMISSION FREQUENCY 869 525 MHz 869 525 MHz 869 525 MHz 869 525 MHz TRANSMITTING POWE...

Page 28: ...vorska 605 563 01 Lanskroun Czech Republic info fencee eu 420 730 893 828 Servis 420 730 893 827 05052021 fencee cz fenceeczech Electric fencing www fencee eu www fenceefarm com www fenceecloud com Stamp and signature of seller ...

Reviews: