Series S40

Panel meter 72x36mm size

Panel meter for Pt100/RTD (2 and 3 wires), and thermocouples J, K, T, E, S, 

R, N, C, L and X with temperature display in degrees celsius (ºC) or fahrenheit 

(ºF). Selectable Pt100/RTD resolution at 1º or 0.1º, and manual offset available. 

Thermocouple measure with internal CJC selectable (enabled or disabled).  

Selectable behavior in case of sensor break (‘to_high’ or ‘to_low’). Reduced 

housing 72x36mm DIN standard. Display in 4 digits and negative sign. Maximum 

and minimum display memory, steps, alarms with single or double setpoints, 5 

levels of brightness, ... Universal AC and DC power modules and up to 2 modules 

for signal retransmission and control.

Model S40-T   

for Pt100 / RTD

     for 

Thermocouples

Panel Meters

FEMA ELECTRÓNICA

USER’S MANUAL

(2264R00)

Summary of Contents for S40-T

Page 1: ...th internal CJC selectable enabled or disabled Selectable behavior in case of sensor break to_high or to_low Reduced housing 72x36mm DIN standard Display in 4 digits and negative sign Maximum and mini...

Page 2: ...on the specified protection level Disconnect the instrument from power before starting any maintenance and or installation action Risk of electrical shock Instrument terminals can be connected to dan...

Page 3: ...he power line a protection fuse acting as disconnection element easily accessible to the operator and identified as a protection device Power H fuse 250mA time lag Power L fuse 400mA time lag 6 7 8 9...

Page 4: ...able 3 Offset drift see table 3 Span drift see table 3 Note span drift includes also the offset drift CJC automatic On Off selectable CJC accuracy 1 0 C CJC thermal drift 0 04 C On sensor break to_hig...

Page 5: ...nu or leaves the Informa tion Menu Operating the Information Menu 36 8 32 5 Mechanical Dimensions mm 72 18 80 69 Panel cut out Configuration Conf Information on the configured input sensor and the deg...

Page 6: ...the menu Allows selec tion of the current option displayed During a value selection menu for example a setpoint value validates the value on display Button UP Moves vertically on the menu Displays the...

Page 7: ...tion See menu for Alarm1 See menu for Alarm1 See menu for Alarm1 Alarm1 Setpoint Hysteresis Delay Active On Inactive Off Max Maximum Min Minimum Alarm management Alarm as max Alarm as min Counts Secon...

Page 8: ...fected on the same way as the setpoint with hysteresis and delays Display Menu Functions on this menu allow for configuration of the visu alization Steps StEP Display changes on predefined steps Value...

Page 9: ...message h udr Hardware underrange The thermocouple signal is lower than minimum readable signal 30mV h oVr Hardware overrange The thermocouple signal is higher than maximum readable signal 80mV d udr...

Page 10: ...ber 2011 Daniel Junc Quality Manager All instruments are warranted against all manufacturing defects for a period of 24 MONTHS from the shipment date This warranty does not apply in case of misuse acc...

Page 11: ...User s Manual S40 T FEMA ELECTR NICA Page 11 T H I S P A G E B L A N K...

Page 12: ...ucts ELECTRONIC INSTRUMENTATION FOR INDUSTRY www fema es FEMA ELECTR NICA S A Altimira 14 Pol Ind Santiga E08210 Barber del Vall s BARCELONA SPAIN Tel 34 93 729 6004 www fema es Fax 34 93 729 6003 inf...

Reviews: