Section INDUSTRIAL . ISOLATED SIGNAL CONVERTERS
23
17.
Precautions on installation
This instrument is warranted against all manufacturing defects for a
period of 36 months, as requested by the European legislation. This
warranty does not apply in case of misuse or accident, and the scope
of the warranty is limited to repair of the instrument, not being the
manufacturer responsible for additional damages or additional costs.
Within the warranty period and after examination by the manufacturer,
the unit will be repaired or substituted when found to be defective.
Extended warranty available at (see section 3)
18.
Warranty
This instrument has been designed and verified conforming to the
61010-1 CE Security Regulation, for industrial applications. Installation
of this instrument must be performed by qualified personnel only. This
manual contains the appropriate information for the installation. Using
the instrument in ways not specified by the manufacturer may lead to a
reduction of the specified protection level. Disconnect the instrument
from all external circuits before starting any maintenance and / or
installation action.
The instrument does not have a general switch and will start operation
as soon as power is connected. The instrument does not have protection
fuse, the fuse must be added during installation.
The instrument is designed to be DIN rail mounted, inside a closed
cabinet, protected from direct impacts. An appropriate ventilation of the
instrument must be assured. Do not expose the instrument to excess of
humidity. Maintain clean by using a humid rag and do NOT use abrasive
products such as alcohols, solvents, etc. General recommendations for
electrical installations apply, and for proper functionality we recommend
: if possible, install the instrument far from electrical noise or magnetic
field generators such as power relays, electrical motors, speed variators,
... If possible, do not install along the same conduits power cables
(power, motor controllers, electrovalves, ...) together with signal and/or
control cables. The use of shielded cables is recommended to prevent
the coupling of environmental electromagnetic noise, connected to earth
only one cable end side. Before proceeding to the power connection,
verify that the voltage level available matches the power levels indicated
in the label on the instrument. In case of fire, disconnect the instrument
from the power line, fire alarm according to local rules, disconnect the air
conditioning, attack fire with carbonic snow, never with water.
Conformity with security regulations EN-61010-1 requires a
closed front cover. There is no need to open the front cover
under normal usage or configuration. The output terminal
prevents the front cover from opening. An open front cover may expose
areas with dangerous voltages. Remove connections with dangerous
voltages before opening. Only to be performed by qualified operators.
Manufacturer
FEMA ELECTRÓNICA, S.A.
Altimira 14 - Pol. Ind. Santiga
E08210 - Barberà del Vallès
BARCELONA - SPAIN
www.fema.es - [email protected]
Products
I4L
The manufacturer declares that the instruments indicated comply with the
directives and rules indicated below.
Electromagnetic compatibility directive 2014/30/EU
Low voltage directive 2014/35/EU
ROHS directive 2015/863/EU
WEEE directive 2012/19/EU
Security rules EN-61010-1
Instrument
Fixed, Permanently connected
Pollution degree 1 and 2 (without condensation)
Isolation
Double
Overvoltage category 2
Electromagnetic compatibility rules EN-61326-1
EM environment Industrial
CISPR 11
Instrument Class A & Class B Group 1
For a detailed declaration see section 3.
Barberà del Vallès, March 2022
Xavier Juncà - Product Manager
According to directive 2012/19/EU, electronic equipment
must be recycled in a selective and controlled way at the
end of its useful life.
19.
CE declaration of conformity
Check the documentation when you find this symbol, to know
the nature of a potential danger and actions to prevent it.
Risk of electrical shock. Instrument terminals can be
connected to dangerous voltage.
Instrument protected with double isolation. No earth
connection required.
Instrument conforms to CE rules and regulations.