FEMA ELECTRÓNICA . SERIES B . Models Bxx-RTU
4
1. Identify the instrument format
2. Power and signal connections
- open the instrument
- connect the power
- close the instrument
3. Configure the instrument
- select the working mode, and the bus configuration
- configure the protocol
4. Advanced configuration (optional)
- configure the instrument alarms
- configure the fast access
- configure other functions: ‘on power up’
, key
‘LE’
and password
5. If the instrument includes analog output (AO) or serial
communications (RTU, S4, S2)
- to include an option to an instrument see section
- to configure an installed option, access the option con
-
figuration menu
- see section
for information regarding the output and
control options available
6. Install the instrument
- mount on panel, wall or hanging
- adjust the brightness level according to your environmen
-
tal needs
1.3 How to use this manual
If this is the first time you are configuring a Series B large
format meter, below are the steps to follow to install and
configure the instrument. Read all the manual sections in
order to have a full and clear view of the characteristics of
the instrument. Do not forget to read the installation precau
-
tions at section
.
The Modbus RTU protocol is a serial communications proto
-
col, based on RS-485 bus, with ‘master’ / ‘slave’ architecture.
Modbus RTU elements needed to understand this manual
are described below:
• ‘registers’: are memory sections inside the ‘slave’ in
-
strument, where the ‘master’ reads or writes data. Reg
-
isters store numerical data. Modbus works with registers
of 16 bits, which allows for numerical values from 32767
to -32767. For displays with 6 digits (display values from
999999 to -199999) registers of 32 bits are needed
.
• ‘coils’: are memory sections inside the ‘slave’ instrument,
where the ‘master’ reads or writes data. Coils store binary
data (‘1’ or ‘0’). Coils are typically used for alarm control
and other elements with 2 states : ‘on’ and ‘off’.
• ‘functions’: are actions that indicate to write or read val
-
ues into ‘registers’ or ‘coils’
• ‘errors’ : Modbus is a protocol with a ‘master’ / ‘slave’ ar
-
chitecture and the ‘master’ will always expect a reply from
the ‘slave’. If a requested ‘function’, ‘register’ or ‘coil’ is not
available, the ‘slave’ will answer with an error. See section
for a list of errors available.
1.4
Modbus RTU definitions
Function
Name
Description
6
Write single register
writes on a single register
16 Write multiple regis
-
ters
writes on multiple registers
3
Read registers
reads on multiple registers
5
Write single coil
writes on a single coil
15 Write multiple coils writes on multiple coils
1
Read coils
reads on multiple coils
Table 1 - Modbus RTU supported functions