FEMA ELECTRÓNICA . Series K . K40-232
2
1. Panel meter K40-232
Display for ASCII protocol with RS-232 bus, in 96
x
48
mm (1/8 DIN) format
Digital panel meter, with ASCII code repeater function, in 96 x 48 mm
size (1/8 DIN) and 4 digits with 20 mm digit height. Reading value,
together with decimal point, are controlled via the RS-232 bus, us
-
ing the ASCII protocol described in this document
.
Reading up to 9999 and -1999.
Three working modes available allow to work with numbers or al
-
phanumerical symbols. Alarms can be controlled directly from the
RS-232 bus or locally from the instrument.
• The ‘Process slave’
mode works with numerical
values, and alarms are controlled locally.
• The ‘Full slave’
-
ues, and alarms are controlled from the bus.
• The ‘Text’
mode works with alphanumerical val
-
ues, and alarms are controlled from the bus.
Bus speed configurable up to 38.400 bps and address configurable
from 1 to 31. Accepts a ‘broadcast’ function at address 128. ‘Watch
-
dog’ function detects if communication with the master is lost.
‘Watchdog’ function can display a message on display and control
the activation of selected alarms
Function ‘bus activity’ is a utility for troubleshooting communica
-
tions
. Function ‘On power up’ defines the alarm
state at start-up
.
Front protection IP65. Connections by plug-in screw terminals. For
industrial applications.
• ‘
Fast access
’ menu to selected functions, accessible with key UP (
5
)
Memory for maximum and minimum reading, password protection,
5 brightness levels.
Index
1. Panel meter K40-232. . . . . . . . . . . . . . . . . . . . . . 2
1.1 How to order . . . . . . . . . . . . . . . . . . . . . . . . 3
. . . . . . . . . . . . . . . . . . . . 3
. . . . . . . . . . . . . . . . . . . . . . 3
. . . . . . . . . . . . . . . . . . . . . . . . . 3
. . . . . . . . . . . . . . . . . . . . . 3
. . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . . . . . . . . . . . . . . . . . . . 4
1.8 Start up sequence . . . . . . . . . . . . . . . . . . . . . 4
. . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . . . . . . . . . . . . . . . . . . 4
. . . . . . . . . . . . . . . . . .
1.12 Mechanical dimensions (mm) . . . . . . . . . . . . . .
1.13 ASCII protocol - Types of frames . . . . . . . . . . . . .
1.14 Frame structure . . . . . . . . . . . . . . . . . . . . . . 7
. . . . . . . . . . . . . . . . . . . . . . 8
1.15.1 Frames ‘WRA’ (35) and ‘OK’ (39)
. . . . . . . . . . . . . . . . . . . . 8
1.15.3 Frames ‘PING’ (32) and ‘PONG’ (33)
1.15.4 Frames ‘RD’ (36) and ‘ANS’ (37)
1.16 Registers in ‘Process slave’ mode
1.17 Registers in ‘Full slave’ mode
. . . . . . . . . . . . . . .10
. . . . . . . . . . . . . . . . .11
. . . . . . . . . . . . . . . . . . . . . .11
1.20 The ‘Alarm status’ register
. . . . . . . . . . . . . . . . 12
. . . . . . . . . . . . . . . . .12
1.22 Messages and errors . . . . . . . . . . . . . . . . . . .13
1.23 Numerical registers : restrictions
1.24 Addresses and ‘broadcast’
. . . . . . . . . . . . . . . .14
. . . . . . . . . . . . . . . . . . .14
. . . . . . . . . . . . . . . . . . .14
1.27 How to operate the menus. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .17
1.28.4 Alarms in ‘Full slave’ and ‘Text’ mode
1.28.5 Alarms in ‘Process slave’ mode
. . . . . . . . . . . . . . . . . . . . . . .
1.28.7 Super fast access . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .20
. . . . . . . . . . . . . . . . . . . .20
. . . . . . . . . . . . . . . . .20
1.28.13 Factory reset . . . . . . . . . . . . . . . . . . . . .20
. . . . . . . . . . . . . . . . . . .20
. . . . . . . . . . . . . . . . . . . . . .20
1.28.16 Access to optional modules
. . . . . . . . . . . . . . . . . . .21
. . . . . . . . . . . . . . . . .22
1.31 To access the instrument . . . . . . . . . . . . . . . . .24
1.32 Modular system . . . . . . . . . . . . . . . . . . . . . .24
1.33 Precautions on installation
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
1.35 CE declaration of conformity
. . . . . . . . . . . . . . . . .
2.1 Module R1. . . . . . . . . . . . . . . . . . . . . . . . . .
2.2 Module T1. . . . . . . . . . . . . . . . . . . . . . . . . .
2.3 Module SSR . . . . . . . . . . . . . . . . . . . . . . . . .27
. . . . . . . . . . . . . . . . . . . . . . . . .27
. . . . . . . . . . . . . . . . . . . . . . . . .28
. . . . . . . . . . . . . . . . . . . . . . . . . .28
2.7 Module S2. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .30
. . . . . . . . . . . . . . . . . . . . . . . . .30
4. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .31
. . . . . . . . . . . . . . . . . .31
4.2 Adapter DRA-M . . . . . . . . . . . . . . . . . . . . . . .31
. . . . . . . . . . . . . . . . . . . . . . . .31
Summary of Contents for K Series
Page 32: ......