The ‘Alarm Status’ register (register 6) is available as a read_only reg
-
ister for the ‘Process slave’ mode and as a read/write register for
the ‘Full slave’ and ‘Text’ modes. This register contains the status of
alarms 1, 2 and 3. Status is active or inactive.
The ‘Alarm Status’ register is 1 character (1 byte) register, with pos
-
sible values from ‘0’ to ‘7’. The alarm status for each value are indi
-
cated at
Note that the ‘Alarm Status’ register contains a value that is the ASCII
code of a number from ‘0’ to ‘7’. The reason is to maintain the pro
-
tocol structure of transmitting ASCII protocols. Note that the value
represented by this character is the binary code representing the sta
-
tus of the alarms. for example, ASCII code 53 represents number ‘5’,
which in binary is ‘0101’, and corresponds with alarm status 3, 2 and
1 in ‘on’, ‘off’ and ‘on’.
1.20 The ‘Alarm status’ register
Register
value
ASCII
character
Alarm 3
status
Alarm 2
status
Alarm 1
status
‘0’
48
off
off
off
‘1’
49
off
off
on
‘2’
50
off
on
off
‘3’
51
off
on
on
‘4’
52
on
off
off
‘5’
53
on
off
on
‘6’
54
on
on
off
‘7’
55
on
on
on
Table 6 - Register ‘Alarm Status’.
1.21 Representable characters
Representable characters are indicated in the following table.
• In numerical modes (‘Full slave’ and ‘Process slave’ modes) only
numbers from ‘0’ to ‘9’, decimal point (‘.’ or ‘,’) and polarity (‘+’ or
‘-’) are representable. Missing polarity is assimilated to positive
polarity. Character ‘+’ is not represented on display.
• In ‘Text’ mode all characters in the table are representable.
Representable characters
Character
Display
Cod. ASCII
Character
Display
Cod. ASCII
Character
Display
Cod. ASCII
Character
Display
Cod. ASCII
0
48
A a
65 / 97
K k
75 / 107
T t
84 / 116
1
49
B b
66 / 98
L l
76 / 108
U u
85 / 117
2
50
C c
67 / 99
M m
77 / 109
V v
86 / 118
3
51
D d
68 / 100
N n
78 / 110
W w
87 / 119
4
52
E e
69 / 101
Ñ ñ
165 / 164
X x
88 / 120
5
53
F f
70 / 102
O o
79 / 111
Y y
89 / 121
6
54
G g
71 / 103
P p
80 / 112
Z z
90 / 122
7
55
H h
72 / 104
Q q
81 / 113
‘.’ ‘,’
44 / 46
8
56
I i
73 / 105
R r
82 / 114
-
45
9
57
J j
74 / 106
S s
83 / 115
+
*(not representable)
43
Table 7 - Representable characters. *Character ‘+’ is accepted as polarity but has no representation on display..
Character ‘+’ is represented as a blank space. Characters not in
-
cluded in this table are represented with 3 horizontal stripes( ).