Signal converter for frequency signals. Internal jumper selection for 5 different ranges of measure,  ranging from 0/40 Hz up 

to 0/40 Khz. Accepts PNP, NPN, Namur and sinusoidal signal types. Provides two types of excitation voltages for transduc

-

ers, 24 Vdc for PNP and  NPN types, and 8,2 Vdc for NAMUR types.

Configure the desired frequency input range and sensor  type by selecting the appropriate jumpers on «MP» module, as 

shown on the tables below:

INPUT RANGE SELECTION

MP

3 2 1

PT2

7

8

9

10

PT1

4 5 6

PT1 - Fine Gain Adjustment. (Additional P2 potentiom

-

eter on input module ME).

PT2 - Trigger Adjustment. Is the voltage level at which the 

input signal is recognized to be as logic ‘1’ or logic ‘0’. It 

can be set empirically operating on potentiometer PT2.

  0/22.5-40 KHz 

1,6

 0/12.5-22.5 KHz 

1,5

 

0/7-12.5 KHz 

1,4

 

0/4-7 KHz 

1

 

0/2.25-4 KHz 

2,6

0/1.25-2.25 KHz  

2,5

  0/700-1250 Hz 

2,4

  0/400-700 Hz 

2

  0/225-400 Hz 

3,6

  0/125-225 Hz 

3,5

 

0/70-125 Hz 

3,4

 

0/40-70 Hz 

3

  SENSOR 

JUMPER 

CONNECTIONS 

 

 

  

«MP»

  Push-Pull  (3 wires) 

10 

3,5,6 

  NPN-PNP (3 wires) 

10 

3,5,6 

  NPN (open collector) 

10,7 

5,6 

  PNP (open collector) 

10,8 

5,6

  NAMUR 

10,9 

4,5 

  Vac<100V 

10 

5,6 

  Vac>100V 

--- 

5,6 

 

RANGE 

JUMPER

 

 

«MP»

 

RANGE 

JUMPER

 

 

«MP»

CONNECTIONS

Power

Fuse

Switch

Sinusoidal

  -

  +

  +

  -

NPN, PNP

  -

  +

 

Namur

  -

  +

Voltage

output

Current 

output

  +

  -

  -

+

The CCT converters allow different power modules in AC and DC. The instrument does not have internal protection fuse. 

Following is a recommendation on value and type of fuse for each power module available.

Fuses

 

Ref. 

   Power 

      Fuse Recommended

 

«0» 

230 Vac  50/60 Hz 

 

 50  mA  Time Lag

 

«1» 

115 Vac  50/60 Hz 

 

100 mA  Time Lag 

 

«2» 

  24 Vac  50/60 Hz 

 

300 mA  Time Lag

 

«3» 

  48 Vac  50/60 Hz 

 

150 mA  Time Lag

 

«6» 

  24 Vdc   

 

300 mA  Fast Fuse 

Reviews: