After installation, test the system as described below to
ensure installation is done correctly. Always make sure the
system is working properly before operating your vessel.
3
VERIFY INSTALLATION
MOBP17012
The MOB+ allows for the pilot to be connected with his xFOB
as a STOP FOB and three more crew members or passengers
to be connected as ALARM FOBs. All xFOBs are universal and
can either be STOP FOB or ALARM FOB. The first connected
xFOB on each boat trip will be assigned as the ”Master” and
become the STOP FOB. Successive connections automatically
become ALARM FOBs.
4
CONNECTION OF xFOBS
MOBP17027
Click the button on your xFOB to connect.
Click the button on your xFOB to connect.
Click the button on your xFOB to disconnect.
When connecting the first xFOB it
becomes the STOP FOB. The STOP
FOB will automatically shut down the
engine(s) if the pilot falls overboard
and disconnect the ALARM FOBs.
Disconnecting the STOP FOB will
disconnect all FOBs regardless of
their connected state and shut down
the engine(s).
Disconnect an ALARM FOB individually
by clicking on the ALARM FOB.
When connecting the second, third and
fourth xFOBs they become ALARM FOBs.
CONNECT
CONNECT
DISCONNECT
STOP FOB
STOP FOB
ALARM FOBs
ALARM FOBS
Start your engine.
START ENGINE
Test the MOB+ by disconnecting with the
xFOB or by submerging the xFOB.
Both described methods are equal in terms of
testing stop functionality.
TEST THE MOB+
Click the xFOB to stop the engine
-The system will now shut down the engine
and disconnect the wireless system.
DISCONNECT
1
Submerge the xFOB in the sea or the ocean
more than 4 inches.
-The system will now go into Man Over Board
mode and shut down the engine. After 6
seconds the xHUB will go into override mode.
Press the xHUB or xFOB to disconnect the
wireless system.
SUBMERSION
2
A bucket of water is not sufficient to test the functionality
of MOB+. Test the system in the sea or ocean/lake.
RECONNECT AND RESTART THE ENGINE
BEFORE TESTING SUBMERSION
The xHUB will give a sound signal and
a GREEN light to indicate a successful
connection.
MOBP17015
SUPPORT
On www.fellmarine.com/videos you will find
installation and user guide videos.
WATCH VIDEOS!
WE ARE HERE TO HELP YOU
Customer care:
Business
hours:
Email:
Web support:
Social Media:
Web:
www.fellmarine.com/customer-care
Monday-Friday 08:00am – 04:00
pm
https://www.fellmarine.com/support/
facebook.com/fellmarine
https://www.fellmarine.com
If any of the ALARM FOBs falls
overboard the xHUB will sound the
MOB Alarm, flashing on the xFOB
indication bar and flashing red on
the light circle. The alarm continues
until the STOP button on the xHUB is
pushed to disengage the alarm.
In an MOB event where the STOP
FOB falls overboard, remaining
passengers with an ALARM FOB
can choose to reconnect one of their
xFOBs first to become the new STOP
FOB, successive connections will
become ALARM FOBs as normal.
MOBP17026
© FELL Technology AS
Page 4/9
GENERAL USE AND INSTALLATION SECTION
MARCH 2018
REV200-0318