11,5 mm
(0.45 inch)
44 mm
(1.7 inches)
28 mm
(1.1 inches)
Measurements and performance
Weight
164g / 5.8oz.
Housing material
ASA / TPU / PBT / POM – RoHS
Temperature range
From -15°C / 5°F to 55°C / 131°F
Voltage Source
10-32Vdc
Power consumption
Active Mode: 180mA (2.5W max. at 13.8Vdc), Standby: <30mA,
<0.4W max. at 13.8V
Fuse
1A-3A
Alarm decibel level
>85db
Kill Switch Relay Max Current Tolerance
5A continuously
Wireless performance
Frequency area
EU:
868 MHz
US:
915 MHz
RF signal (in)
10 dBm max.
RF signal (out)
10 dBm max.
4D Antenna diversity
Certifications and compliance
Radio - xHUB
EU:
R&TTE, EN 300 328,
Maritime/CE
US:
FCC Part 15C
EMC - xHUB
EU:
EN 301 489-01
(V1.9.2), Class A
US:
CISPR 16-1
Flammability - xFOB
IEC 60950 1&22, CE-UL94
Immersion xFOB
IEC 60945, IP68, Maritime/CE - 3m / 10ft. water resistant
RoHS (2002/95/EC) compliant materials
ABYC A-33 compliant
228 mm
(9 inches)
166 mm
(6.5 inches)
49 mm
1.9 inches)
66 mm
(2.6 inches)
62 mm
(2.45 inches)
52 mm
(2 inches)
17 mm
(0.7 inch)
External Antenna
Self-locking Nut
xFOB Connection Indicator
Pairing, Override
and Stop Button
Light and Sound Alarm
Internal Antenna
• How can I override the system if the system fails or if I
have lost the xFOB?
-
If the system fails use the End Cap Connector attached to the
main xHUB cable to mechanically override the system.
-If you have lost your xFOB press and hold the button on the
xHUB for 10 seconds to put the system in Override Mode.
• I already have an existing kill switch. Can I install MOB+?
-Yes. MOB+ is installed using wires from your existing kill
switch. Please see installation guide for instructions
• I have a boat made from metal. Can I install MOB+?
-Actual signal reduction, if any, will vary from boat to boat.
Should the signal be noticeably worse, we recommend
using an external antenna to put on the top side of the helm,
supplied from FELL Marine.
• Can passengers start the boat if I were to fall over board?
-Yes, this is one of the main features of MOB+. 6 seconds
after a MOB Event the system lets passenger restart the
engine to pick up the missing person in the water.
TIME-OUT FUNCTIONS
FAQs
TECHNICAL SPECIFICATIONS - xFOB™
TECHNICAL SPECIFICATIONS -xHUB™
Connected: 20h Time-Out:
The normal xFOB to xHUB
connection will automatically time-out after 20h and shut down
your engine(s). This is to prevent unnecessary battery drainage of
the xFOB battery. Click xFOB again to reconnect.
Override Mode: 8h Time-Out:
Override Mode automatically times
out after 8h and shuts down your engine(s) to prevent engine start
if the boat is left unobserved.
MOB Mode: 2h Time-Out:
MOB Mode automatically times out
after 2h shuts down your engine(s). This is to prevent engine
start if the boat is left unobserved after leaving the boat without
disconnecting the xFOB.
MOBP17006
MAN OVER BOARD SEQUENCE
Drive
MOB
dStart
™
Makes it possible for
passengers to start the engine 6
seconds after a MOB incident to quickly
rescue the person in the water
Range up to 50
feet. 4D antenna
diversity
ensures a robust
connection.
Should you fall
over board the
engine will stop
as you hit the
water
MOBP17007
MOBP17008
MOBP17009
Measurements and performance
Weight
10g / 0.35oz.
Housing material
ASA / TPU / POM
Temperature range
From -15°C / 5°F to 55°C / 131°F
Voltage Source
Coin Cell Battery - 3V nominal
Power consumption
0.3 µA in sleep (0.00033 W) 30 mA in active mode (0.098W)
Battery life
300 hours continuous usage
Wireless performance
Frequency area
EU:
868 MHz
US:
915 MHz
RF signal (in)
10 dBm max.
RF signal (out)
10 dBm max.
4D Antenna diversity
Battery xFOB
Battery type
CR2032
Battery voltage
3V lithium battery
Certifications and compliance
Radio - xFOB
EU:
R&TTE, EN 300 328,
Maritime/CE
US:
FCC Part 15C
EMC - xFOB
EU:
EN 301 489-01
(V1.9.2), Class A
US:
CISPR 16-1
Flammability - xFOB
IEC 60950 1&22, CE-UL94
Immersion xFOB
IEC 60945, IP68, Maritime/CE - 3m / 10ft. water resistant
RoHS (2002/95/EC) compliant materials
ABYC A-33 compliant
© FELL Technology AS
Page 2/9
MARCH 2018
REV200-0318