If the instrument locks-up or requires a hard shut-off for any other reason, hold down power button for 
10 seconds.  This will force the F-760 power to turn off.  Then, the instrument can be restarted. 

To take a measurement, power on the F-750 Produce Quality Meter.  The current model will be 
displayed. To change the model refer to the “Select Model” section on Page 3 of the manual. Hold the 
sample to the lens so that it makes contact with the perimeter of the bracket around the lens. Press the 
square/start button to record a new measurement.   

During the measurement the instrument will switch to the scan display and collect and process the data.  
As the measurement is being collected, large blocks will appear at the bottom of the display screen.  
Keep the sample in place as all blocks progress. The measurement is taking place during the 1

st

 and 2

nd

 

block going across screen.  The 3

rd

 block is for processing data, the 4

th

block is for saving measurements.  

At the 5

th

block, the measurement is complete and displays the record to be reviewed.  Once at the 3

rd

 

block or “processing” the sample can be removed from instrument. 

The data is stored to a removable SD card. To remove, press into the unit and the card will eject. To 
replace, insert metal side first with the label facing the back of the unit. 

A Glossary of Vocabulary Definitions is located at the end of this manual.  

Navigating Menus 

Use the power button to turn on the F-750.  After the instrument powers on, the display will show the 
current model loaded on the unit and the battery life.  Instructions at the bottom of the display indicate 
to press the square/start button to record a new measurement or press the right arrow to view the 
main menu.   

 

 

 

 

 

Use the right arrow to get to the Main Menu.  Once at the Main Menu, the left arrow can be used to go 
back or exit to the previous screen.  The Main Menu consists of three options, select model, browse 
records, or setup instrument. 

 

Apple DM and TSS  

 

battery life (%) 

 

Press (square/start) to record a new measurement 

Press right arrow to view the main menu 

Summary of Contents for F-750

Page 1: ...F 750 Produce Quality Meter Operation Manual...

Page 2: ......

Page 3: ...6 How to Generate a Model 7 Partial Least Squares Basics 11 B coefficient Regression 11 How to Collect Spectra and Reference Values 12 Cleaning and Maintenance 13 Firmware Update Procedure 13 Warning...

Page 4: ...t parameters such as planning for harvest sequences and improving crop management techniques For quantitative analysis of complex samples fast and inexpensive spectroscopic methods are preferable to t...

Page 5: ...weighted coefficients to the spectrum are applied 3 Coefficients are summed over the weighted spectra 4 A predicted concentration is reported by the summation Unpacking the F 750 The F 750 will arrive...

Page 6: ...1st and 2nd block going across screen The 3rd block is for processing data the 4th block is for saving measurements At the 5th block the measurement is complete and displays the record to be reviewed...

Page 7: ...ear Using the scale coefficient 1 and scale coefficient 2 menus a new value to use for the scale coefficient can be entered The scale coefficient is from the regression vector Press the left arrow to...

Page 8: ...n The options are to create a new training set delete a training set or modify an existing training set Create New Training Set At the create new training set menu enter the name to use for this new t...

Page 9: ...r 0 65 The lamp state option is used to turn the lamp on or lamp off Press the down up to turn off on The lamp automatic gain which is used to fine tune how much the logic has control of the gain can...

Page 10: ...F 750 Instruction Manual rev 3 26 2014 1554 NE 3rd Ave Camas WA 98607 USA Phone 360 833 8835 Fax 360 833 1914 sales felixinstruments com http www felixinstruments com 7 How to Generate a Model...

Page 11: ...nstrument to the computer and open the software 2 Insert the SDcard to the computer 3 Prompt user for the location of the calibration files 4 Load Slov Golay scans into the program 5 Prompt user for t...

Page 12: ...Leave One out Cross Validation k 1 cross validation 9 Program determines if there are outliers and allows the user to label outliers 10 If outliers exist systematically remove each outlier and determ...

Page 13: ...60 833 8835 Fax 360 833 1914 sales felixinstruments com http www felixinstruments com 10 13 Graph the B coefficient or weighted regression coefficients 14 Check the B coefficient for noise If noise is...

Page 14: ...pectra and determine what preprocessing is required 4 Select useful region 5 Preform the Regression Cross Validation 6 Evaluate results B coefficient Regression Perform the regression by calculating t...

Page 15: ...nstruction Manual rev 3 26 2014 1554 NE 3rd Ave Camas WA 98607 USA Phone 360 833 8835 Fax 360 833 1914 sales felixinstruments com http www felixinstruments com 12 How to Collect Spectra and Reference...

Page 16: ...nuggly installed The rubber bumper and the case of the F 50 can be wiped clean with a cloth Firmware Update Procedure The firmware of the F 750 is updated by connecting the instrument to a computer us...

Page 17: ...y and M Golay 1964 Smoothing and Differentiation of Data by Simplified Least Squares Procedures Analytical Chemistry 36 8 1627 1639 M Sjostrom and S Wold 1983 A multivariate calibration problem in ana...

Page 18: ...plication of commercially available low cost miniaturized NIR spectrometers to the assessment of the sugar content of intact fruit Plant Physiol 27 1175 1186 K Walsh R Long and S Middelton 2007 Use of...

Page 19: ...orbance of chlorophyll This will make up a set of properties that will be predicted and displayed after a model file is loaded on the F 750 NIPALS Non linear Iterative Partial Least Squares iterative...

Page 20: ...f the model For example a dry matter model with a RMSE of 0 0123 has an error of 1 23 DM or a 1 23 prediction error An acceptable amount of error is determined by the type of property being predicted...

Page 21: ...are to answer your technical questions by phone or by e mail at support felixinstruments com Felix Instruments contact information Felix Instruments 1554 NE 3rd Ave Camas WA 98607 USA Phone 800 767 01...

Page 22: ...ntent in fish dry matter of cheese titratable acids quantification as well as many other characteristics 2 How do I recharge the batteries of the F 750 a To recharge the batteries twist to remove the...

Page 23: ...not authorized by Felix Instruments Material and equipment covered hereby which is not manufactured by Seller is to be covered only by the warranty of its manufacturer Seller shall not be liable to th...

Page 24: ...750 Instruction Manual rev 3 26 2014 1554 NE 3rd Ave Camas WA 98607 USA Phone 360 833 8835 Fax 360 833 1914 sales felixinstruments com http www felixinstruments com 21 F 750 PRODUCTION TEST CHECK SHEE...

Reviews: