Table 4.4-3 :Detailed Pin Function Of COM Port On IVGM
15
16
Make sure Meter & CT are connected between house loads and grid, and follow the Smart Meter
direction sign on CT, refer to Figure 4.4-4.
Hybrid solar inverter
Hybrid solar inverter
Position
1
2
3
4
5
6
7
8
Note
Function
485_A2
485_B2
485_A3
485_B3
485_A3
485_B3
RY_4
RY_5
RS485-2 For Meter
RS485-3 For Remote Monitor
Figure 4.4-4 Smart meter connection
Inverter side
Grid side
4.5 DRMS Connection
DRMS(Demand response enabling device) is used for Australia and New Zealand installation
(also used as remote shutdown function in European countries), in compliance with Australia and
New Zealand safety requirements( or European countries). Inverter integrates control logic and
provides an interface for DRMS. The DRMS is not provided by inverter manufacturer. Detailed
connection of DRMS & Remote Shutdown are shown below:
Step 1.
Screw this plate off from the inverter. See Figure 4.6-1.
Figure 4.5-1 DRMS interface
\
Step 2.
Plug out the RJ45 terminal and dismantle the resistor on it. Plug the resistor out, leave
the RJ45 terminal for next step.
Figure 4.5-2 operating steps
P3
GN
P2
BN-WH
P1
BN
P8
ORG-WH
P4
BU-WH
P7
ORG
P6
GN-WH
P5
BU
P2
BN-WH
P1
BN
P1
P8
P8
P1
IVGM side
Meter side
Note
:
The cable should be made refer to Figure 4.4-3
Figure 4.4-3 Smart meter cable