13
en
Filling the coolant container.
Prevent the flow of liquid along the cable into the socket outlet or into the core
drill unit, as this can lead to electric shock. Tie a bow in the cable near the plug,
so that any liquid can drip off.
Do not use the magnetic base drill unit if the cooling lubricant system is defective. Check for
proper seal against leaks and for cracks in the hoses. Prevent liquids from entering or penetrat-
ing electrical components.
Filling the mounted coolant container
(figure 5)
Unscrew the cap from the coolant container.
Fill in pump-feedable cooling lubricant, e.g.
Fein cutting oil.
Screw the cap onto the coolant container
again.
Filling the dismounted coolant container
(figure 6)
Pull the empty coolant container out of the
drill stand housing of the magnetic core drill.
Unscrew the cap from the coolant container.
Fill in pump-feedable cooling lubricant, e.g.
Fein cutting oil.
Screw the cap onto the coolant container
again.
Insert the filled coolant container into the
holder on the drill stand housing intended for
this purpose.
WARNING
Coolant container
Upper closing cap
max. 500 ml max. 17 fl. OZ.
max. 500 ml max. 17 fl. OZ.
Coolant container
Upper closing cap
OBJ_BUCH-0000000142-002.book Page 13 Monday, November 18, 2013 11:13 AM