Fitting the motor housing
1. Position the two pressure pieces (1) [on both sides].
2. Insert the electronics (2), the tool head with field coil (3) and the slide switch (4).
3. Position the cable grommet (5).
4. Position the cable clamping piece (6).
5. Screw in the screw (7) [1.5
±0.1Nm
].
6. Position the motor housing (8).
7. Screw in the eight screws (9) [1.5
±0.1Nm
].
Tools:
- Torx T15