background image

Instruction Manual

Radar Motion Detector MWD BP

10/13

Manual MWD BP.doc

as 07/21/2006

FEIG ELECTRONIC GmbH

7 Notes

-

 

The MWD BP is a 2 channel device. While opening parameter entry first the odd address used to open chan-
nel 1 will displayed. The following even device address activates channel 2.

-

 

In factory settings relay 1 with change over contacts is assigned to channel 1 (display „

|

 .“

) and relay 2 with

normally open contact is assigned to channel 2 (display „

| |

.“

). It is possible to change relay assignments via

parameter entry.

-

 

Only the odd device address of channel 1 can be changed. The address of channel 2 results from the following
even address.

-

 

Common parameter (e.g. firmware info, profiles...) can be displayed/changed with even or odd device ad-
dress.

8 Connections

X1

8

NC

1

Com

1

NO

1

GND 24V NO

2

Com

2

1

2

3

4

5

6

7

Backside view, Contact status for power off

9 Technical data

Dimensions

135x65x130mm (BxHxT)

Protective system

IP 65

Power supply

12-27 V AC / 12-30 V DC

Power consumption

typ. 1,0 W, max. 2,4 W

Admissible working temperature

-20 °C .. +60 °C

Storing temperature

-30 °C .. +75 °C

Air moisture

< 95 % not condensing

Transmit frequency

typ. 24,125 GHz

Output power (EIRP)

typ. 40 mW, max. 100 mW

Output relay

max. switching load

1 A / 30 V AC/DC (resistive load)

min. switching load

1 mA / 5 V DC
Use external protective wiring for inductive load !

Maximum mounting height

7 m

Summary of Contents for MWD BP

Page 1: ...Instruction Manual 07 21 2006 Manual MWD BP doc Radar Motion Detector MWD BP...

Page 2: ...installation Since despite of all our efforts errors may not be completely avoided we are always grateful for your useful tips The installation instructions given in this manual are based on advantage...

Page 3: ...________ 6 3 3 Close Parameter Entry ______________________________________________________ 7 3 4 Show Service Parameter _____________________________________________________ 7 4 Standard Parameter Li...

Page 4: ...m Thus each motion within the detection range is recorded analyzed by a logic and transmitted to the gate resp barrier control by connecting potential free change over contacts Range of application En...

Page 5: ...o avoid incorrect release there must not be any objects in motion within the radiation field There must not be any fluorescent tubes within the radiation field of the detector It should be avoided tha...

Page 6: ...ress Channel 2 displayed address 1 Actual device address is displayed with blinking digit and decimal point 1 2 Right short Select address value Increment or decrement value Changed values doesn t bli...

Page 7: ...rd parameter menu service parameter menu display off b Button on Motion Detector MWD BP Key Key press Description Action Display Example 1 Left long Close parameter entry from standard parameter menu...

Page 8: ...0 3 0 off 1 low 3 high relay function r 0 4 0 off 1 channel 1 for channel 1 2 channel 2 for channel 2 3 channel 1 OR channel 2 4 channel 1 AND channel 2 output on delay time t 0 F 0 0s 1 F 0 2s 3 0s...

Page 9: ...els 6 Profiles Profile No 1 2 3 4 5 6 7 8 9 Channel 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 Sensitivity Level 9 9 9 9 9 9 9 9 9 Direction appr appr appr appr appr appr appr appr appr Human Detection 2 2 V...

Page 10: ...d The address of channel 2 results from the following even address Common parameter e g firmware info profiles can be displayed changed with even or odd device ad dress 8 Connections X1 8 NC 1 Com 1 N...

Page 11: ...WD BP doc as 07 21 2006 FEIG ELECTRONIC GmbH 10Type Approval 10 1 Europe CE When used according to regulation this radio equipment conforms with the basic requirements of article 3 and the other relev...

Page 12: ...15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency...

Page 13: ...VDE 0105 as well as the fire and accident prevention standard VBG4 Please switch off current supply prior to opening the device and make sure that it remains off If an indicator lamp goes out this is...

Reviews: