4 Standard Parameter List
7-Segment Display
Parameter Name
Parameter
Name
Value Range
Parameter Definition
Sensitivity Level
L.
1
..
9
,
A
..
F
1 = low
:
7 = middle
:
9 *
:
F = high
direction
d.
0
..
2
0 = off
1 = approaching *
2 = departure
human detection
h.
0
..
3
0 = off *
1 = low
:
3 = high
vehicle detection
u.
0
..
3
0 = off *
1 = low
:
3 = high
Cross traffic suppression
C.
0
..
3
0 = off *
1 = low
:
3 = high
Object tracking
O.
0
..
3
0 = off *
1 = low
:
3 = high
relay function
r.
0
..
4
0 = off
1 = channel 1 *
(
for
channel 1)
2 = channel 2 *
(
for
channel 2)
3 = channel 1 OR channel 2
4 = channel 1 AND channel 2
output on delay time
t.
0
..
F
0 = 0s *
1..F = 0.2s .. 3.0s
(value x 0.2s)
output off delay Time
T.
0
..
F
0 = 0s
1 = 0.2s
(value x 0.2s)
2 = 0.4s *
3..F = 0.6s .. 3.0s
relay operating mode
o.
0
..
1
0 = normally de-energized *
1 = normally energized
Profiles
P.
0
..
9
0 = parameter changed after profile setting (only displayed !)
1 = Profile No 1:
initiate
Factory
Setting
*
2..9 = Profile No. 2..9
* factory setting
Note:
Resetting to factory values can be effected by parameter name “profile” with parameter value “1”. Alternatively