IDENTIFICATION
ID CPR60
Page 13 of 22
6 Technical Data
Tab. 2: Technical data
ID CPR60
Dimension (W x H x D)
max. 41 mm x 41 mm x 6,5 mm
Weight
approx. 10 g
Temperature Range
Operating
-25 °C up to +70 °C (-13 °F up to +158 °F)
Storage
-40 °C up to +85 °C (-40 °F up to +185 °F)
Humidity
max. 95 % (not condensing)
Power Supply
1
•
for digital circuit:
3,3 V DC ± 5 %
max power consumption: 100 mA
•
for analog circuit:
5 V DC ± 5 %
Ripple: 0...250 kHz < 10 mVpp
up from 250 kHz < 0,1 mVpp
max power consumption peak (excl. SAM): 300 mA
typ. power consumption with RFID (excl. SAM): 200 mA
Current Consumption
< 400 mA (without SAM)
< 25mA Standby mode
< 50mA Standby Mode with Wake-Up-by-Card
Interfaces
USB
Full-Speed (12 Mbit/s), Self-Powered Device
SPI
Slave Device (up to 16 Mbit/s)
RS232-LVTTL
4 800
– 921 600 Baud
Driver
USB Driver, PC/SC-Driver (WHQL)
Windows 7, 8 and 10 32/64 Bit
Windows Server 2012 and 2016
Connector (Vcc, USB , SPI, Smart Card)
80 pole Board-to-Board (see:
Software Development Kits
Windows (C++, .NET, Java), Linux (C++, Java), Raspberry Pi
RFID Interface
ISO/IEC 14443-A/-B
(ISO-Mode: 106, 212, 424, 848 kbit/s;
EMVCo Mode: 106 kBit/s)
ISO 15693
Operating Frequency
13,56 MHz
Output Power
typ. 450 mW
Antenna Connection
U.FL-Socket for external 50 Ohm antenna
1
The reader has to be supplied by a limited power supply according to EN 62368-1 PS1.