11.11 Direction Detection (Dir. Mode, Direction Mode)
The settings for direction detection can only be selected for the 2-channel traffic detector VEK MNE2 .
DIP
USB
Direction detection
OFF
OFF
turned off
(factory defaults)
ON
ON
turned on
Complex algorithms have been integrated into the 2-channel detector to provide direction-dependent detec-
tion of vehicles on double-loops. The directional logic generates logic output signals that may be output via
the hardware outputs, depending on settings Simultaneously, the detector independently counts the logic
signals.
In every logic, the loop that is covered first determines the count or direction of travel. For example, if loop 1
is covered first, the output is issued and the count in direction A is performed.
The factory default setting issues the output for the direction of travel A via hardware output 1 and for direc-
tion of travel B via hardware output 2. However, the assignment of the outputs may be changed.. (see chap-
ter 11.8)
The service program Detector Tool displays the counters. It should be noted that the counters overflow
at 65535 (216) and are cleared automatically.
The counts in the detector are not protected against loss of power!
11.12 Direction Logic
Depending on the application, different evaluation logics can be selected in the logic module.
The adjustment of the direction of logic is possible only with activated direction detection!
DIP
USB
Direction Logic
OFF
D2
Continuous signal 2
(factory defaults)
D1
Continuous signal 1
DB
Continuous signal, both loops
ON
F1
Wrong-direction driver 1
F2
Wrong-direction driver 2
FE
Feig
SF
Loop free
BS
both loops
PB
Parking bay
OFF