10 Elements on the Front
1
2
3
4
6
5
7
8
O
N
1
2
3
4
O
N
1
2
3
4
6
5
7
8
O
N
10.1 LED Display
The front of the detector has 2 LEDs to indicate the detector status of each loop channel.
LED red
LED blue
Description
off
off
Supply voltage missing
off
an
Loop free, detector ready
an
an
Object detected on loop
an
off
Loop failure
-
flashes, 5 Hz Frequency alignment running
-
flashes, 1 Hz Loop failure repaired or overwritten setting
*
flashes
flashes
Frequency output after alignment (see example)
Example: Frequency output via LED for 57 kHz:
Tens digits Units
The frequency output for loop channels 1 and 2 is sequential.
*
Indication, that the detector is operational again after a previously resolved loop failure.
†
Change(s) by the service program of one or more settings via the USB interface