![Feig Electronic VEK M2E-2-B Operating Instructions Manual Download Page 15](http://html1.mh-extra.com/html/feig-electronic/vek-m2e-2-b/vek-m2e-2-b_operating-instructions-manual_3900967015.webp)
Operating instructions
VEK M2E-2
FEIG ELECTRONIC GmbH
03/06
15
Relay locking: (only for type VEK M2E-2-D)
Relay locking is activated as soon as
DIP-switch 7
is in
"ON"
position. In this mode,
presence is indicated by the relay of the loop which has been occupied first. The signal
output of the other channel remains locked until both loops have been crossed or the time-
out has expired.
DIP-switch
7
Output function
OFF
Presence detection
ON
Relay locking
Time-out: (only for type VEK M2E-2-D)
The time-out is selected in the output mode relay locking, with the help of
DIP-switch 8
. In
case of presence detection, it can be used to choose the signal output for channel 2.
DIP-switch
Output function
8
Presence detection
Relay locking
OFF
Permanent signal during
presence on loop 2
Time-out 10s
for both channels
ON
Pulse when
leaving
loop 2
Time-out 5s
for both channels
8.3. Type VEK M2E-2 -E
Directional logic
type VEK M2E-2-E:
a) single vehicle
1
2
DIP-switch 8 "ON"
pulse signal
DIP-switch 8 "OFF"
permanent signal
Ð
1
2
Ð
1
2
Relay 1
Æ
permanent direction signal
'on'
Ð
1
2
Relay 1
Æ
directional pulse
Relay 1
Æ
permanent direction signal
'remains'
Ð
1
2
Relay 1
Æ
permanent direction signal
'off'